Skip to main content
Siemens 6AG1407-0KR02-4AA0 — Industrial PCs

Siemens 6AG1407-0KR02-4AA0 SIPLUS S7-400 PS407 Power Supply

MPN6AG1407-0KR02-4AA0

Siemens SIPLUS S7-400 PS407 power supply, 6AG1407-0KR02-4AA0, 10A wide-range UC 120/230V, conformal coated, 5V DC/10A backplane bus, 24V DC/1A, 2 slots.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

6AG1407-0KR02-4AA0 — Performance
ParameterValue
Required slots2
6AG1407-0KR02-4AA0 — Electrical
ParameterValue
Power loss (typ.)20 W
6AG1407-0KR02-4AA0 — Mechanical
ParameterValue
Width50 mm
Height290 mm
Depth217 mm
Weight (approx.)1 200 g
6AG1407-0KR02-4AA0 — Environmental
ParameterValue
Operating temperature, max.60 °C; = Tmax
Operating temperature, min.0 °C; = Tmin
Ambient temperature vs. altitude / pressureTmin ... Tmax at 1 080 hPa ... 795 hPa (-1 000 m ... +2 000 m) // Tmin ... (Tmax - 10 K) at 795 hPa ... 658 hPa (+2 000 m ... +3 500 m) // Tmin ... (Tmax - 20 K) at 658 hPa ... 540 hPa (+3 500 m ... +5 000 m)

Product details

SIPLUS S7-400 PS407 — conformal coated for harsh environments

The 6AG1407-0KR02-4AA0: This is the SIPLUS variant of the standard 6ES7407-0KR02-0AA0 PS407 power supply, distinguished by conformal coating on the PCB assembly. The coating protects against condensation, corrosive gases, and dust ingress — a common requirement in food-and-bev, chemical, and offshore installations where the standard unit would risk tracking failures over time. Rated for redundant use, the unit occupies 2 slots in an S7-400 rack and delivers 5 V DC at up to 10 A to the backplane bus with no base load required, plus 24 V DC at up to 1 A for I/O or interface modules. The wide-range input accepts 120 V AC, 230 V AC, 110 V DC, or 230 V DC without jumper changes — the auto-sensing primary handles 50/60 Hz from 47 to 63 Hz. Typical power loss is 20 W, with a maximum inrush current of 63 A (1 ms half-width).

Backplane bus capacity and battery backup

The 5 V DC backplane bus is rated for 10 A continuous — sufficient for a fully loaded S7-400 rack with CPU, multiple I/O, and communication processors. The 24 V DC bus supplies 1 A and is idling-proof, meaning it holds regulation even with no load. Both rails are short-circuit protected. An optional backup battery (2x lithium AA, 3.6 V / 2.3 Ah) maintains the RAM and real-time clock during mains interruptions. The unit holds the output for 20 ms on mains failure per the stored energy time spec, and supports NAMUR buffering recommendations for process-industry brownout ride-through.

Environmental range and altitude derating

The operating temperature range is 0 °C to 60 °C at standard atmospheric pressure (1,080 hPa to 795 hPa, corresponding to -1,000 m to +2,000 m altitude). Above 2,000 m, the maximum ambient temperature derates by 10 K up to 3,500 m, and by 20 K up to 5,000 m — a critical consideration for high-altitude installations or unventilated cabinets in warm climates.

Sourced through authorized industrial distribution channels. No stock-holding claim is made; the unit is quoted to order.

Frequently asked questions

What is the closest pin-compatible alternative to 6AG1407-0KR02-4AA0?

The standard non-coated equivalent is 6ES7407-0KR02-0AA0. The SIPLUS variant adds conformal coating for harsh environments but is otherwise pin-compatible and functionally identical.

What compliance documentation does this brand provide for 6AG1407-0KR02-4AA0?

The unit carries equipment protection class I (protective earth required) and overvoltage category II. The SIPLUS line typically includes RoHS and REACH declarations; specific UL or IEC certifications are not listed in this record and should be confirmed against the full product drawing.

MPN
6AG1407-0KR02-4AA0