Siemens 6DL1134-6AF00-0PH1
MPN6DL1134-6AF00-0PH1
Active
SIMATIC ET 200SP HA, analog input module, AI 8xU/I/TC/4xRTD 2-/3-/4-wire HA suitable for terminal block, H1, N0, H0 color code CC00, channel diagnostics
$754.38Ref. price · indicative, final on quote
StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jun 2026
Specifications
Inputs & Signal Ranges
| Parameter | Value |
|---|---|
| Input range: 0 to 20 mA | Yes |
| Input range: 4 to 20 mA | Yes |
| Input range: -10 to +10 V | Yes; 16 bit incl. sign |
| Input range: -5 to +5 V | Yes; 16 bit incl. sign |
| Input range: -80 to +80 mV | Yes; 16 bit incl. sign |
| Input range: 0 to 600 Ohm | Yes; 15 bit |
| RTD type: Pt100 | Yes; 16 bit incl. sign |
| RTD type: Pt200 | Yes; 16 bit incl. sign |
| Current measurement: 2-wire transducer | Yes |
| Current measurement: 4-wire transducer | Yes |
| Input resistance (0 to 20 mA) | 50 Ω |
| Input resistance (4 to 20 mA) | 50 Ω |
| Input resistance (-10 to +10 V) | 100 kΩ |
| Permissible input voltage, max. (destruction limit) | 24 V |
| Permissible input current, max. (destruction limit) | 40 mA |
| Max. shielded signal cable length | thermocouples: shielded cable length max. 200 m, voltages: shielded cable length max. 600 m, loop resistance max 8 kOhm; measuring ranges RTD: shielded cable length max. 600 m, cable resistance (single) max. 75 ohm, current measurement: shielded cable length max. 800 m |
Measurement Performance
| Parameter | Value |
|---|---|
| Resolution (bit incl. sign), max. | 16 bit |
| Measurement principle | integrating (Sigma-Delta) |
| Temperature measurement error (±) | 0.002 %/K; ±0.005 % / K at thermocouple |
| Voltage measurement error (±) | 0.1 % |
| Current measurement error (±) | 0.1 % |
| Interference voltage suppression (at interference frequency) | 10 / 50 / 60 / 400 Hz |
| Common-mode interference suppression, min. | 90 dB |
| Common-mode voltage, max. | 15 V |
Diagnostics & Monitoring
| Parameter | Value |
|---|---|
| Wire-break detection | Yes; channel-by-channel TC, current 4 ... 20 mA, R and RTD |
| Diagnostic alarm | Yes |
| Diagnostics function | Yes |
| Limit value alarm | Yes; two upper and two lower limit values in each case |
| Supply voltage monitoring | Yes |
Isolation
| Parameter | Value |
|---|---|
| Isolation: channels to backplane bus | Yes |
| Isolation: between channels | No |
| Isolation test voltage | 1 500 V DC/1 min, type test |
Power
| Parameter | Value |
|---|---|
| Rated value (DC) | 24 V |
| Power loss, typ. | 1.95 W |
| Reverse polarity protection | Yes |
Environmental
| Parameter | Value |
|---|---|
| Operating temperature, horizontal mounting, max. | 70 °C |
| Operating temperature, horizontal mounting, min. | -40 °C |
| Operating temperature, vertical mounting, max. | 60 °C |
| Operating temperature, vertical mounting, min. | -40 °C |
Mechanical
| Parameter | Value |
|---|---|
| Width | 22.5 mm |
| Height | 115 mm |
| Depth | 138 mm |
| Weight, approx. | 150 g |
MPN
6DL1134-6AF00-0PH1