Skip to main content
Siemens 6DR5616-.....-.... — Flow & Proportional Control

Siemens 6DR5616-.....-.... SIPART PS2 Positioner, FOUNDATION

MPN6DR5616-.....-....
Active

Siemens SIPART PS2 smart electropneumatic positioner, 6DR5616-.....-...., FOUNDATION Fieldbus, Ex/nEx, single-acting, stainless steel enclosure, flameproof (Ex d), for pneumatic linear and part-turn actuators.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

6DR5616-.....-.... — Approvals
ParameterValue
RoHS complianceSince: 31-12-16
REACH SVHC declarationReach Information
Export control (ECCN)AL : N / ECCN : N
6DR5616-.....-.... — Other specifications
ParameterValue
Group codeR3P2
Product group4759
Product classC: products manufactured / produced to order, which cannot be reused or re-utilized or be returned against credit.
SeriesSIPART PS2

Product details

The Siemens 6DR5616-.....-.... is a SIPART PS2 smart electropneumatic positioner with FOUNDATION Fieldbus communication, rated for Ex/nEx environments. It is single-acting, housed in a stainless steel flameproof (Ex d) enclosure, and designed for pneumatic linear and part-turn actuators.

This class of positioner is used in process valve control loops — throttling a control valve on a steam line, positioning a butterfly valve on a chemical feed, or stroking a linear actuator on a compressor recycle loop. The FOUNDATION Fieldbus variant fits into a distributed control system (DCS) that speaks FF H1, common in refineries, power plants, and pharmaceutical batch processes.

RoHS compliance is confirmed since 31 December 2016. REACH candidate list information is available on request.

Group and product codes for traceability

The Group Code is R3P2 and the Product Group is 4759. These are internal Siemens classification codes used for BOM cross-referencing and spares identification in some ERP systems. They do not affect fit or function but can help match the correct variant when the full order code suffix is not legible on the nameplate.

Frequently asked questions

What compliance documentation is available for this positioner?

RoHS compliance is confirmed since 31 December 2016. REACH Article 33 duty-to-inform information is available. Export control is AL N / ECCN N.

What do the Group Code R3P2 and Product Group 4759 mean?

These are Siemens internal classification codes used for BOM cross-referencing and spares identification. They do not affect fit or function but can help verify the correct variant when the full order code suffix is not legible.

How do I source this positioner?

As a class C made-to-order item, it is quoted against an RFQ. Submit your full order code and quantity for a firm price and lead time.

MPN
6DR5616-.....-....