Skip to main content
Siemens 6EP1332-1SH43 — DIN Rail Power Supplies

Siemens 6EP1332-1SH43 Power Supply, 2.5 A, NEC Class 2

MPN6EP1332-1SH43

Siemens SITOP PSU100C power supply, 6EP1332-1SH43, 2.5 A rated output, DC input 110-300 V, NEC Class 2, IP20, DIN rail mount.

$48.69 – $98.00Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

6EP1332-1SH43 — Electrical – Output
ParameterValue
Rated output voltage (DC)24 V
Rated current2.5 A
Rated current range0 ... 2.5 A; +55 ... +70 °C: Derating 2%/K
Output power at rated voltage/current (typ.)8 W
Output voltage characteristicControlled, isolated DC voltage
Output 1 rated voltage (DC)24 V
Output voltage adjustableYes
6EP1332-1SH43 — Electrical – Input & Efficiency
ParameterValue
Supplied active power (typ.)60 W
Efficiency88 %
Power supply network type1-phase AC or DC
Maximum4.8 A
6EP1332-1SH43 — Protection & Isolation
ParameterValue
Ingress protection (IP) ratingIP20
Protection classClass II (without protective conductor)
Short-circuit proof outputYes
Short-circuit protection designConstant current characteristic
Galvanic isolation input/outputYes
Galvanic isolation (SELV / standards)Safety extra-low output voltage Uout acc. to EN 60950-1 and EN 50178
6EP1332-1SH43 — Connections
ParameterValue
Electrical connection typescrew-type terminals
Input terminalsL, N: 1 screw terminal each for 0.5 ... 2.5 mm2 single-core/finely stranded
Output terminals+, -: 2 screw terminals each for 0.5 ... 2.5 mm²
6EP1332-1SH43 — Mechanical
ParameterValue
Mounting methodSnaps onto DIN rail EN 60715 35x7.5/15
Enclosure width72 mm
Enclosure height90 mm
Enclosure depth52.6 mm
Side-by-side mountableYes
Mounting clearance, left0 mm
Mounting clearance, right0 mm
Mounting clearance, top20 mm
Mounting clearance, bottom20 mm
6EP1332-1SH43 — Environmental
ParameterValue
Operating temperature range-20 ... +70 °C; with natural convection
Storage temperature range-40 ... +85 °C
Transport temperature range-40 ... +85 °C
Current limitation of inrush current at 25 °C maximum46 A
6EP1332-1SH43 — Approvals & EMC
ParameterValue
CE markingYes
UL approvalYes; cULus-Listed (UL 508, CSA C22.2 No. 107.1), File E197259; cURus-Recognized (UL 60950, CSA C22.2 No. 60950), File E151273, NEC class 2 (acc. to UL 1310)
CSA approvalYes; cULus-Listed (UL 508, CSA C22.2 No. 107.1), File E197259; cURus-Recognized (UL 60950, CSA C22.2 No. 60950), File E151273, NEC class 2 (acc. to UL 1310)
NEC Class 2Yes
ATEX approvalNo
IECEx approvalNo
UL HazLoc approvalNo
cCSAus Class I Div 2 (hazardous loc.)No
EAC approvalYes
Shipbuilding approvalABS, BV, DNV, GL, LRS
EMC – emission standardEN 55022 Class B
EMC – immunity standardEN 61000-6-2
6EP1332-1SH43 — Reliability & Features
ParameterValue
MTBF at 40 °C3 723 563 h
Equipment bridgingYes
Status indicators / displayGreen LED for output voltage OK
6EP1332-1SH43 — Electrical
ParameterValue
Adjustable Output Voltage22.2 ... 26.4 V

Product details

The Siemens 6EP1332-1SH43 delivers a rated output of 2.5 A from a DC input spanning 110 to 300 V. The NEC Class 2 rating (per UL 1310) means the output is limited-energy, which simplifies wiring in industrial control panels — no separate overcurrent protection required on the load side for most applications. The UL/cULus listing (UL 508, CSA C22.2 No. 107.1) confirms it meets North American industrial control equipment standards. With IP20 protection, it's suited for dry indoor environments inside a cabinet; the housing doesn't seal against moisture ingress, so keep it behind a gland plate or enclosure door.

The 2.5 A rated current is the continuous output at 25 °C ambient. Above 55 °C, derate at 2 % per Kelvin up to 70 °C. The DC input range of 110 to 300 V covers nominal 110 V, 125 V, and 220 V DC systems commonly found in railway, telecom, and industrial battery-backed buses. The wide tolerance handles dips and surges without dropping out. Internal fuse protection means no external fuse holder is needed on the output, though the feeder should have a miniature circuit breaker — 10 A characteristic B or 6 A characteristic C recommended upstream. MTBF at 40 °C is 3,723,563 hours.

CE marking, EAC approval, and DNV GL marine type approval are on file. Galvanic isolation provides safety extra-low output voltage (SELV) per EN 60950-1 and EN 50178, so it's suitable for feeding control circuits that require separation from mains.

Frequently asked questions

What is the 6EP1332-1SH43's top clearance requirement?

The specified top clearance is 20 mm for proper ventilation and airflow around the unit.

MPN
6EP1332-1SH43