6EP4137-0GE00-0AY0
Siemens 6EP4137-0GE00-0AY0
MPN6EP4137-0GE00-0AY0
Active
SITOP BAT1600 24 V DC 38 Ah Pb battery module with maintenance- fee closed lead-acid battery for SITOP UPS1600
$387.35Ref. price · indicative, final on quote
StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jun 2026
Specifications
| Parameter | Value |
|---|---|
| Type of electrical connection | Plug-in terminals with screwed connection |
| Output voltage at DC rated value | 24 V |
| Charging current maximum | 9 A |
| Output current rated value | 40 A |
| For power supply unit | 1 screw terminal each for 0.5 ... 16 mm² for + BAT and - BAT |
| Depth of the enclosure | 165 mm |
| Width of the enclosure | 394 mm |
| Height of the enclosure | 212 mm |
| Wall mounting | No |
| Mounting height | 262 mm |
| S7 rail mounting | No |
| Installation width | 330 mm |
By ambient temperature11 ▾
| Parameter | Value |
|---|---|
| At 20 °C typical | 10 a |
| At 30 °C typical | 5 a |
| At 40 °C typical | 2.5 a |
| At 50 °C typical | 1.25 a |
| At 0 °C recommended | 28 V |
| At 10 °C recommended | 27.8 V |
| At 20 °C recommended | 27.3 V |
| At 30 °C recommended | 26.8 V |
| At 40 °C recommended | 26.6 V |
| At 50 °C recommended | 26.3 V |
| At -10 °C recommended | 28 V |
All specifications+32 ▾
| Parameter | Value |
|---|---|
| Standard rail mounting | No |
| Ambient temperature during storage | In addition to the storage temperature, additional factors, such as storage duration and charging status during storage, have a major impact on the potential service life. This means batteries should preferably be stored fully charged for short periods of time in a dry, cool and frost-proof (temperature range 0 to +20 °C) location. |
| CE marking | Yes |
| UL approval | Yes |
| CSA approval | Yes |
| As approval for USA | UL-Listed (UL 621010, CSA C22.2 No. 107.1) |
| Shipbuilding approval | ABS, DNV GL |
| Top | 50 mm |
| ATEX | No |
| Left | 0 mm |
| Right | 0 mm |
| Bottom | 50 mm |
| C-Tick | Yes |
| DNV GL | Yes |
| Typical | capacity falls to 80 % of original capacity (according to EUROBAT) |
| During storage | -20 ... +40 °C |
| Number of cells | 2 |
| Battery capacity | 38 A·h |
| During operation | -15 ... +50 °C |
| During transport | -30 ... +70 °C |
| Mounting | Floor mounting |
| Other information | Specifications at rated input voltage and ambient temperature +25 °C (unless otherwise specified) |
| Operating data note | For storage, mounting and operation of batteries, the relevant DIN/VDE regulations or country-specific regulations (e.g. VDE 0510 Part 2/EN 50272-2) must be observed. |
| Protection class IP | IP20 |
| Product component included | 2x Maxi Fuse 50 A/32 V |
| cCSAus, class 1, division 2 | No |
| Design of the overload protection | Valve control |
| Operating resource protection class | Class III |
| Display version for normal operation | Three-color: green = Buffer ready; yellow = Buffer endangered; red = Buffer not possible |
| For control circuit and status message | 1 screw terminal each for 0.2 ... 2.5 mm² |
| American bureau of shipping europe ltd. | Yes |
| Relative temporary capacity loss at 20 °C in a month typical | 3 % |
MPN