Skip to main content
Siemens 6ES7134-6PA01-0BU0 — Analog Input Modules

Siemens 6ES7134-6PA01-0BU0 Power Measurement Module, 24 V

MPN6ES7134-6PA01-0BU0
Active

Siemens ET 200SP power measurement module, 6ES7134-6PA01-0BU0, 24 V DC, 58 mm depth, width 20 mm, height 73 mm, current production.

$144.78 – $428.37Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

6ES7134-6PA01-0BU0 — Inputs & Signal Ranges
ParameterValue
Max. shielded signal cable length200 m
6ES7134-6PA01-0BU0 — Diagnostics & Monitoring
ParameterValue
Diagnostic alarmYes
Limit value alarmYes
6ES7134-6PA01-0BU0 — Isolation
ParameterValue
Isolation: channels to backplane busYes
Isolation: between channelsNo
Isolation test voltageBetween channels and backplane bus, 24 V supply: Routine test, 1 920 V AC, 2 s; between backplane bus and 24 V supply: Type test, 707 V DC
6ES7134-6PA01-0BU0 — Power
ParameterValue
Rated value (DC)24 V
Power loss, typ.1 W; 3x 5 A input current, 3x 230 V AC
6ES7134-6PA01-0BU0 — Environmental
ParameterValue
Operating temperature, horizontal mounting, max.60 °C
Operating temperature, horizontal mounting, min.-30 °C
Operating temperature, vertical mounting, max.50 °C
Operating temperature, vertical mounting, min.-30 °C
6ES7134-6PA01-0BU0 — Mechanical
ParameterValue
Width20 mm
Height73 mm
Depth58 mm
Weight, approx.45 g

Product details

Module overview

It measures current on up to three phases plus neutral, along with voltage, frequency, power, and energy. Firmware version V8.0 is shipped from the factory, matching TIA Portal libraries at that revision.

I/O and diagnostics

The module provides 256 bytes of input data and 20 bytes of output data. It supports I&M data (I&M0 to I&M3) for asset tracking, diagnostic alarm, limit value alarm, and hardware interrupt (monitoring up to 16 freely selectable process values). Overflow/underflow detection and channel-not-available handling are built in.

Base unit type U0 is required; this module works only with BU type U0 in 2-wire connection. Maximum cable length is 200 m for both shielded and unshielded runs. Isolation is tested at 1 920 V AC for 2 s between channels and backplane/24 V supply, and 707 V DC between backplane and 24 V supply. Power loss is typically 1 W under a 3x 5 A input at 230 V AC load. Firmware can be updated in the field, and automatic encoding simplifies replacement without manual address assignment. Isochronous mode is not supported — this module uses the standard ET 200SP backplane communication.

Frequently asked questions

What is the depth of this module?

The depth is 58 mm.

What is the width of this module?

The width is 20 mm.

MPN
6ES7134-6PA01-0BU0