Skip to main content
Siemens 6ES7142-1BD40-0XA0 — Digital Output Modules

6ES7142-1BD40-0XA0 SIMATIC DP EM 142, 4 DO 24V/2A, IP65

MPN6ES7142-1BD40-0XA0

Siemens SIMATIC DP, Extended module EM 142, ET 200X, 4 digital outputs DC 24V/2A, 5-pole M12, IP65, spare part.

$150.00 – $160.02Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

6ES7142-1BD40-0XA0 — Outputs
ParameterValue
Digital outputs4
6ES7142-1BD40-0XA0 — Electrical
ParameterValue
Output current, resistive load, max.100 Hz
Output current at signal "1" (rated)2 A; At 24 V DC
Output current, max. per circuit / per module2.4 A
Output voltage at signal "1" (min.)2L+ (-0,8 V)
Residual current at signal "0", max.0.5 mA
Current consumption from backplane bus (5 V DC), max.28.5 mA
Power dissipation (typ.)2.1 W
Inductive shutdown voltage clampTyp. (2L+) -47 V
Load resistance, upper limit4 kΩ
Load resistance, lower limit12 Ω
Isolation between channelsNo
Isolation test voltage500 V DC
6ES7142-1BD40-0XA0 — Protection & Diagnostics
ParameterValue
Short-circuit protectionYes; Electronic
Short-circuit response threshold (typ.)3 A
Redundant load controlYes; only outputs of the same group
Output can drive a digital inputYes
6ES7142-1BD40-0XA0 — Performance
ParameterValue
Switching frequency, lamp load, max.1 Hz
6ES7142-1BD40-0XA0 — Mechanical & Connection
ParameterValue
Cable length, unshielded, max.30 m
Width87 mm; Width module 60 mm
Height110 mm
Depth55 mm
Weight (approx.)250 g

Product details

The 6ES7142-1BD40-0XA0 is a SIMATIC DP Extended Module EM 142 for the ET 200X family — a spare-part designation for a 4-output digital slice that switches 2 A per channel at 24 V DC through a 5-pole M12 connector, sealed to IP65. It's built for distributed I/O in wet or dusty environments — the IP65 rating means the module and its M12 ports stand up to washdown and airborne grit on a conveyor line or packaging cell.

Each output is rated 2 A at 24 V DC for signal '1', with a permissible range from 5 mA minimum to 2.4 A maximum per channel — so it drives solenoids, contactors, and indicator lamps within that window, but not motor starters directly. The total current is temperature-dependent: 6 A per channel up to 20 °C, derated to 4 A at 55 °C. That derating curve matters if the module sits inside a crowded, warm cabinet or near a heat source. Switching speed hits 100 Hz with resistive loads, but drops to 1 Hz on lamp loads — incandescent inrush will limit cycle rate, so don't plan fast strobe or pulsed lamp control on these outputs. Short-circuit protection is electronic and per-channel, so a faulted output won't take down the whole group. The response threshold is typ. 3 A, which clears a short before the backplane fuse or power supply trips.

The module measures 110 mm high, 87 mm wide (60 mm module width), and 55 mm deep — it mounts on the ET 200X base module and connects via the 5-pole M12 connector, so no terminal block wiring inside the panel. Power draw from the backplane bus is 28.5 mA at 5 V DC; the load voltage 2L+ draws up to 12 mA without load. Isolation is tested at 500 V DC between the backplane bus and all other circuits, with 75 V DC/60 V AC between different circuits. No channel-to-channel isolation, so outputs share a common reference — plan your load grouping accordingly.

Marked as a spare part with lifecycle stage 'current' — meaning Siemens still supports it as a replacement for existing ET 200X installations, but it's not the go-to for new designs. The ET 200X platform has been superseded by ET 200SP and ET 200eco PN. For a line-down situation, this is the exact drop-in for a failed EM 142. No rewiring, no re-addressing — same M12 pinout, same backplane bus.

Frequently asked questions

What is the closest functional second-source — 6ES7148-4FA00-0AB0?

The 6ES7148-4FA00-0AB0 is a different form factor (65 x 90 x 130 mm) with 16 digital inputs and SIL 3 / PL e safety rating — it will not drop into the same ET 200X base module or M12 wiring scheme. No direct second-source exists for the EM 142.

What is the listed depth and width?

Depth is 55 mm; width is 87 mm overall (60 mm module width).

Will 6ES7142-1BD40-0XA0 drop into a panel specified around 6ES7148-4FA00-0AB0?

No — the 6ES7148-4FA00-0AB0 is a safety I/O module for ET 200SP, with different dimensions, backplane bus, and M12 pinout. The EM 142 only fits ET 200X basic modules.

MPN
6ES7142-1BD40-0XA0