Skip to main content
Siemens 6ES7151-1BA02-0AB0 — PLC Communication Modules

Siemens 6ES7151-1BA02-0AB0 IM151-1 High Feature, 12 Mbit/s

MPN6ES7151-1BA02-0AB0

Siemens SIMATIC DP, Interface module IM151-1 High Feature for ET 200S, order code 6ES7151-1BA02-0AB0, PROFIBUS DP to 12 Mbit/s, 244-byte I/O per direction, isochronous mode, lifecycle stage current.

$88.56Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

6ES7151-1BA02-0AB0 — Communication
ParameterValue
Transmission rate, max.12 Mbit/s
Diagnostics functionYes
Isochronous modeYes
6ES7151-1BA02-0AB0 — Electrical
ParameterValue
Power loss (typ.)3.3 W
Isolation test voltage500 V DC
6ES7151-1BA02-0AB0 — I/O
ParameterValue
Input data area244 byte
Output data area244 byte
6ES7151-1BA02-0AB0 — Environmental
ParameterValue
Operating temperature, max.60 °C
Operating temperature, min.0 °C
6ES7151-1BA02-0AB0 — Mechanical
ParameterValue
Width45 mm
Height119.5 mm
Depth75 mm

Product details

The Siemens 6ES7151-1BA02-0AB0 is the SIMATIC DP interface module IM151-1 High Feature, acting as the PROFIBUS DP head-end for an ET 200S distributed I/O station — the part that takes the DP cable from the master and exposes the backplane bus to up to 63 plugged-in I/O modules. Bus connection is via a 9-pin D-sub and the termination module is included in the package, so the segment terminator is not a separate line item at commissioning. Lifecycle stage is recorded as current on this order code.

PROFIBUS DP side — what the master sees

Transmission runs RS 485, PROFIBUS DP, with a maximum transmission rate of 12 Mbit/s — set the master port to the same baud and the segment length per the PROFIBUS cable table. Each direction carries up to 244 bytes of I/O data; the station supports direct data exchange (slave-to-slave communication), so a second DP slave can be a publisher to this node without a master round-trip. Electronics are isolated from the PROFIBUS DP segment; isolation is tested with 500 V DC.

Backplane sizing and I/O capacity

Up to 63 ET 200S modules can be connected behind the interface, with 244 bytes of inputs and 244 bytes of outputs as the address-volume ceiling per station.

Power and supply behavior

From supply voltage 1L+ the module draws up to 200 mA, with a typical power loss of 3.3 W. Mains/voltage failure stored energy time is 20 ms. There is no isolation between the supply voltage and the electronics, and no isolation between the backplane bus and electronics either; segregation against PROFIBUS DP is the only galvanic barrier on this module.

Panel-side envelope and approvals

Footprint on the DIN rail is 45 mm wide, 119.5 mm high, 75 mm deep; operating envelope is 0 °C to 60 °C. CE mark and UL approval are both recorded on this code, so it ships into a UL-listed panel build without a separate approval loop on the BOM line.

Frequently asked questions

What is the operating temperature range of the 6ES7151-1BA02-0AB0?

The listed operating envelope is 0 °C minimum to 60 °C maximum.

What fieldbus does the 6ES7151-1BA02-0AB0 speak?

It speaks PROFIBUS DP only, on RS 485, up to 12 Mbit/s; it does not support PROFINET IO.

How much I/O data can the 6ES7151-1BA02-0AB0 carry per station?

Up to 244 bytes of inputs and 244 bytes of outputs, with up to 63 ET 200S modules plugged in behind the interface.

What compliance marks are on the 6ES7151-1BA02-0AB0?

CE mark and UL approval are both recorded on this order code.

MPN
6ES7151-1BA02-0AB0