Siemens 6ES7151-3BA23-0AB0 — PLC Communication Modules

Siemens 6ES7151-3BA23-0AB0 IM 151-3 PN, PROFINET IRT

MPN6ES7151-3BA23-0AB0

Siemens ET 200S, IM 151-3 PN interface module, 2-port PROFINET, IRT, MRP, 100 Mbit/s, current lifecycle.

$277.50 – $392.00Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

6ES7151-3BA23-0AB0 — Communication
ParameterValue
Transmission rate, max.100 Mbit/s
Diagnostics functionYes
6ES7151-3BA23-0AB0 — Electrical
ParameterValue
Power loss (typ.)3.3 W
Isolation test voltage500 V
6ES7151-3BA23-0AB0 — I/O
ParameterValue
Input data area256 byte
Output data area256 byte
6ES7151-3BA23-0AB0 — Environmental
ParameterValue
Operating temperature, max.60 °C
Operating temperature, min.0 °C
6ES7151-3BA23-0AB0 — Mechanical
ParameterValue
Width60 mm
Height119.5 mm
Depth75 mm; with mounting rail

Product details

What it does for your line

The 6ES7151-3BA23-0AB0: Two PROFINET ports run at 100 Mbit/s with IRT, so isochronous real-time data gets deterministic delivery for servo drives and high-speed interlocks. MRP media redundancy is built in, letting you close a ring and survive a single cable break without dropping the bus.

Mounting and diagnostics

Width is 60 mm, depth 75 mm on the DIN rail—fits a standard ET 200S rack without crowding adjacent modules. Diagnostics via the group error SF (red) and bus fault BF (red) LEDs cut troubleshooting time. The link LED confirms port activity. Prioritized startup gets the I/O communicating faster after a power cycle. Mains failure hold-up of 20 ms gives you time for an orderly shutdown. Power dissipation is only 3.3 W typical, so heat buildup is minimal in a dense cabinet. Isolation between Ethernet and electronics is tested at 500 V, good for noisy environments.

Sourcing posture

UL and CE approvals are listed; compliance documentation is available from the manufacturer for your file.

Frequently asked questions

Does this module support PROFINET IRT?

Yes, IRT is supported, enabling deterministic real-time communication.

What compliance approvals does it carry?

It carries both UL approval and CE mark.

MPN
6ES7151-3BA23-0AB0