Skip to main content
Siemens 6ES7193-6AG00-0AA0 — PLC Communication Modules

Siemens 6ES7193-6AG00-0AA0 Bus Adapter BA 2xLC, 20 mm

MPN6ES7193-6AG00-0AA0
Active

Siemens SIMATIC bus adapter BA 2xLC, 6ES7193-6AG00-0AA0, 2x LC glass fiber connections, 100BASE-FX, 20 mm width.

$203.20 – $603.85Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

6ES7193-6AG00-0AA0 — Identification
ParameterValue
Hardware functional status (FS)from FS04
6ES7193-6AG00-0AA0 — Environmental
ParameterValue
Operating temperature, horizontal install, min.-30 °C
Operating temperature, horizontal install, max.60 °C
Operating temperature, vertical install, max.50 °C
Operating temperature, vertical install, min.-30 °C
6ES7193-6AG00-0AA0 — Mechanical
ParameterValue
Width20 mm
Height69.5 mm
Depth59 mm
6ES7193-6AG00-0AA0 — Other specifications
ParameterValue
Weight, approx.40 g
Number of LC ports2; Wavelength of 1 270 ... 1 380 nm, corresponds to 100BASE-FX
Number of PROFINET interfaces1; 2 ports (switch) LC Multimode Glass Fibre
Multimode graded-index fiber 50/125 μm3 km
Multimode graded-index fiber 62.5/125 μm3 km
Installation altitude above sea level, max.5 000 m; restrictions for installation altitudes > 2 000 m, see ET 200SP system manual

Product details

The Siemens 6ES7193-6AG00-0AA0 is a SIMATIC bus adapter BA 2xLC that plugs onto an ET 200SP interface module to add two LC glass fiber ports for PROFINET. It operates as a two-port switch on 100BASE-FX, supporting multimode fiber up to 3 km.

Temperature and mounting orientation

Rated ambient temperature depends on mounting orientation: up to 60 °C in horizontal installation, derated to 50 °C when mounted vertically. Both hold down to -30 °C. Altitude limit is 5 000 m, but above 2 000 m refer to the ET 200SP system manual for derating guidelines.

Frequently asked questions

What is the physical size of this bus adapter?

Width 20 mm, depth 59 mm, height 69.5 mm. Fits a standard ET 200SP slice slot.

What is the maximum ambient temperature for horizontal vs vertical mounting?

Horizontal: -30 to 60 °C. Vertical: -30 to 50 °C.

MPN
6ES7193-6AG00-0AA0