Skip to main content
Siemens 6ES7215-1HF40-0XB0 — PLCs (Programmable Logic Controllers)

Siemens 6ES7215-1HF40-0XB0 PLC, Fail-Safe CPU 1215 FC, 24V DC

MPN6ES7215-1HF40-0XB0
Active

Siemens S7-1200F CPU 1215 FC, 6ES7215-1HF40-0XB0, fail-safe CPU, 24V DC, 130 x 100 x 75 mm, -40 to 70 °C, MRP manager/client, PROFIsafe, OPC UA server, cULus/CE.

$637.54 – $1,710.00Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

6ES7215-1HF40-0XB0 — I/O
ParameterValue
Digital inputs14; Integrated
Digital outputs10; Relays
6ES7215-1HF40-0XB0 — Processor & Memory
ParameterValue
Execution time, bit operations (typ.)0.08 µs; / instruction
Execution time, word operations (typ.)1.7 µs; / instruction
Execution time, floating-point arithmetic (typ.)2.3 µs; / instruction
Size, max.8 kbyte; Size of bit memory address area
6ES7215-1HF40-0XB0 — Programming
ParameterValue
Programming language: FBDYes; incl. failsafe
Programming language: LADYes; incl. failsafe
Programming language: SCLYes
6ES7215-1HF40-0XB0 — Electrical
ParameterValue
Rated value (DC)24 V
Current consumption (rated)500 mA; CPU only
Permissible range, lower limit (DC)20.4 V
Permissible range, upper limit (DC)28.8 V
Power loss (typ.)12 W
6ES7215-1HF40-0XB0 — Environmental
ParameterValue
Temperature, min.-40 °C
Temperature, max.70 °C
Operating temperature, min. (horizontal mounting)0 °C
Operating temperature, max. (horizontal mounting)55 °C
6ES7215-1HF40-0XB0 — Mechanical
ParameterValue
Width130 mm
Height100 mm
Depth75 mm
Weight (approx.)585 g
6ES7215-1HF40-0XB0 — Communication
ParameterValue
Interface typePROFINET

Product details

The 6ES7215-1HF40-0XB0 is a fail-safe CPU with 24 V DC supply and PROFIsafe for safety communication.

Key Specs That Matter for Your BOM

Supply voltage: 24 V DC, minimum holding voltage is L+ minus 4 V DC. That means if your 24 V rail sags to 20 V (common in long cable runs), the CPU holds. No need for a separate boost converter unless you go below that. This covers most industrial enclosures, but watch the upper limit if the panel sits next to a motor drive without ventilation. MRP support: yes, as MRP redundancy manager and/or MRP client. So it handles ring topology directly — no external media redundancy module required. Good for fail-safe rings where you need both management and client roles. OPC UA server onboard — if the customer wants to pull data to an MES or SCADA without a separate gateway, this saves a slot and a license. MODBUS TCP/IP and UDP support, so legacy and non-Siemens field devices can talk without a protocol converter.

Certifications and Compliance

The CPU carries cULus and CE mark. That covers the typical North American and EU project requirements. No ATEX on the label, so if you need explosive-atmosphere rating, you'll need an additional barrier or a different model.

Width 130 mm, height 100 mm, depth 75 mm.

Frequently asked questions

What is the minimum supply voltage for this CPU?

The minimum holding voltage is L+ minus 4 V DC. With a nominal 24 V DC supply, the CPU tolerates drops down to approximately 20 V DC without browning out.

Does the CPU support MRP as redundancy manager and client?

Yes, it supports MRP as both redundancy manager and MRP client, allowing direct integration into ring topologies without an external module.

What certifications does this PLC have?

It carries cULus and CE mark. No ATEX or other hazardous-location approvals are listed.

MPN