Skip to main content
Siemens 6ES7288-1SR60-0AA1 — DIN Rail Power Supplies

Siemens 6ES7288-1SR60-0AA1 S7-200 SMART CPU SR60, 30 kbyte,

MPN6ES7288-1SR60-0AA1

Siemens S7-200 SMART CPU SR60, 6ES7288-1SR60-0AA1, 30 kbyte program memory, 144 byte inputs/outputs, PROFINET, RS-485, PID control, -40 to 70 °C.

$336.00 – $562.29Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

6ES7288-1SR60-0AA1 key specifications
ParameterValue
TypeHardware clock, no battery backup
InterfaceRS 485 (max. 187.5 kbps)
Type of memoryDDR
Type of input voltageDC
Test voltage at air discharge8 kV
Test voltage at contact discharge4 kV
Current output, max.300 mA; 24 V DC Sensor Power
Inrush current, max.16.3 A; at 264 V
Current consumption, max.370 mA; At 120 V AC
Current consumption (rated value)220 mA; at 240 V AC
Interference emission via line (AC current cables)EN 61000-6-4, interference emission: Intended for use in industrial areas.
For signal "0", max. (Permissible quiescent current)1 mA

All specifications

6ES7288-1SR60-0AA1 additional specifications
ParameterValue
Power loss, max.25 W
S7 communicationYes
PROFINET IO deviceYes; I-Device since V2.5
PROFINET IO controllerYes; Since V2.4
Number of RS 485 interfaces1
Supports protocol for PROFINET IOYes; RT Controller (since FW V2.4) & I-Device (since FW V2.5)
Number of industrial ethernet interfaces1
Rail mountingYes; Standard - DIN rail
Installation altitude, max.2 000 m
Installation altitude, min.-1 000 m
Vertical installation, max.55 °C
Vertical installation, min.-20 °C
Horizontal installation, max.60 °C
Horizontal installation, min.-20 °C
Depth81 mm
Width175 mm
Height100 mm
Weight, approx.611.5 g
Fall height, max.0.3 m; five times, in product package
CE markYes
FBDYes
LADYes
RAMYes
STLYes
Max.70 °C
Min.-40 °C
FlashYes
Inputs144 byte; 256 bit of digital inputs & 56 words of analog inputs
RS 485Yes
TCP (IP)Yes
ForcingYes
Outputs144 byte; 256 bit of digital outputs & 56 words of analog outputs
PresentYes; Maintenance free, RTC requires 7 days.
120 v ACYes
230 v ACYes
IsolatedYes; Transformer isolated, 1,500V AC
PROFIBUSYes; Via CM DP module
As clientYes
As serverYes
SupportedYes
Backup time7 d
Memory size30 kbyte; Program memory
AutocrossingYes
Inputs, max.128 byte; Per device
Outputs, max.128 byte; Per device
Updating time4 ms; The minimum value of the update time also depends on the communication component set for PROFINET IO, on the number of IO devices and the quantity of configured user data.
For signal "0"5 V DC at 1 mA
For signal "1"15 V DC at 2.5 mA
PID controllerYes; PID closed-loop control function: Continuous controller outputs, binary controller outputs, automatic/manual mode, max. 8 loops
Shielded, max.500 m
AutonegotiationYes
ParameterizableYes; 6 Single phase: 4 HSCs at 200 kHz; 2 HSCs at 30 kHz 4 A/B phase: 2 HSCs at 100 kHz; 2 HSCs at 20 kHz
"0" to "1", max.10 ms; max.
"1" to "0", max.10 ms; max.
RJ 45 (Ethernet)Yes
Rated value24 V
Unshielded, max.150 m
Micro memory cardYes; microSDHC Card (optional)
Source (sink input)Yes
On lamp load, max.30 W; 30 W with DC, 200 W with AC
Up to 40 °C, max.36
At "0" to "1", max.12.8 ms
At "0" to "1", min.0.2 ms
Programming packageSTEP 7 Micro/WIN SMART
Between the channelsNo
For signal "1", typ.4 mA
Deviation per day, max.120 s; within 120s/month at 25 °C
Number of pulse outputs3
Number of relay outputs24
Status (control variable)Yes
Storage (transport, max.)1 080 hPa
Storage (transport, min.)660 hPa
Transmission rate, max.100 Mbit/s
For bit operations, typ.150 ns; / instruction
Number of digital inputs36; Integrated
For word operations, typ.1.2 µs; / instruction
Number of digital outputs24; Relays
With resistive load, max.2 A
Hardware clock (real-time)Yes
Memory available for user data20 kbyte
Permissible range, lower limit47 Hz
Permissible range, upper limit63 Hz
For backplane bus (5 v DC), max.1.4 A; max. 5 V DC for EM bus
Between the channels, in groups of2
For floating point arithmetic, typ.3.6 µs; / instruction
Number of connectable IO devices, max.8
Automatic detection of transmission rateYes; 10/100 Mbit/s
Limit class a, for use in industrial areasYes; EN 61000-6-4, interference emission: Intended for use in industrial areas.
Operation at 25 °C without condensation, max.95 %
Of the pulse outputs, with resistive load, max.1 Hz
Of which inputs usable for technological functions4; HSC (High Speed Counting)

Product details

CPU SR60 — what fits in the panel

The Siemens 6ES7288-1SR60-0AA1 is a S7-200 SMART CPU SR60 with 30 kbyte program memory, 144 bytes of inputs and 144 bytes of outputs (256 bits digital plus 56 words analog each side). It runs on 120 V AC or 230 V AC supply, transformer-isolated at 1500 V AC, and operates from -40 °C to 70 °C. PROFINET IO controller is built in, supporting both client and server roles with autonegotiation and autocrossing. For legacy fieldbus, RS-485 at up to 187.5 kbps is on-board; PROFIBUS requires the CM DP module. The minimum PROFINET update time is 4 ms, though that depends on the number of IO devices and configured data. Programming is supported in LAD, FBD, and STL — yes, all three. The hardware clock has no battery backup; the RTC is maintenance-free but needs 7 days of power-on to retain time. Forcing is supported, and the PID closed-loop controller handles up to 8 loops with continuous or binary outputs and auto/manual mode.

This CPU is an active catalog number in the S7-200 SMART line. It carries CE marking, which covers the EU regulatory framework for industrial control equipment. No UL, CSA, or other agency marks are listed on this record — verify with your quality documentation if a specific approval is required for your panel.

Integration notes

Mounts on standard DIN rail. Spring-cage terminals on the I/O accept 0.2–2.5 mm² solid or ferruled stranded — strip to 8 mm. The RS-485 port is shielded, max 500 m at 187.5 kbps. High-speed counters are parameterizable: six single-phase channels (four at 200 kHz, two at 30 kHz) or four A/B-phase channels (two at 100 kHz, two at 20 kHz). The DDR memory type is flash-backed for program retention.

Frequently asked questions

Does this CPU support LAD and FBD programming?

Yes, LAD, FBD, and STL are all supported.

What compliance documentation is available for this CPU?

CE marking is listed on the record. No UL, CSA, or other agency marks are confirmed here. Verify with your quality team if specific approvals are required.

MPN
6ES7288-1SR60-0AA1