Siemens 6ES7288-1ST20-0AA1 — DIN Rail Power Supplies

Siemens 6ES7288-1ST20-0AA1 S7-1200 CPU, 12 KB program memory

MPN6ES7288-1ST20-0AA1

Siemens S7-1200 CPU, 6ES7288-1ST20-0AA1, 12 KB program memory, 144-byte I/O, PROFINET, RS-485, PID, 8 high-speed counters.

$223.00Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

6ES7288-1ST20-0AA1 key specifications
ParameterValue
TypeHardware clock, no battery backup
InterfaceRS 485 (max. 187.5 kbps)
Type of memoryDDR
Type of input voltageDC
Test voltage at air discharge8 kV
Test voltage at contact discharge4 kV
Current output, max.300 mA; 24 V DC Sensor Power
Inrush current, max.11.7 A; at 28.8 V
Current consumption, max.720 mA; 24 V DC
For signal "0" residual current, max.10 µA
Interference emission via line (AC current cables)EN 61000-6-4, interference emission: Intended for use in industrial areas.
For signal "0", max. (Permissible quiescent current)1 mA

All specifications

6ES7288-1ST20-0AA1 additional specifications
ParameterValue
Power loss, max.20 W
S7 communicationYes
PROFINET IO deviceYes; I-Device since V2.5
PROFINET IO controllerYes; Since V2.4
Number of RS 485 interfaces1
Supports protocol for PROFINET IOYes; RT Controller (since FW V2.4) & I-Device (since FW V2.5)
Number of industrial ethernet interfaces1
Rail mountingYes; Standard - DIN rail
Installation altitude, max.2 000 m
Installation altitude, min.-1 000 m
Vertical installation, max.50 °C
Vertical installation, min.0 °C
Horizontal installation, max.60 °C
Horizontal installation, min.0 °C
Depth81 mm
Width90 mm
Height100 mm
Weight, approx.320 g
Fall height, max.0.3 m; five times, in product package
CE markYes
FBDYes
LADYes
RAMYes
STLYes
Max.70 °C
Min.-40 °C
FlashYes
Inputs144 byte; 256 bit of digital inputs & 56 words of analog inputs
RS 485Yes
TCP (IP)Yes
ForcingYes
Outputs144 byte; 256 bit of digital outputs & 56 words of analog outputs
PresentYes; Maintenance free, RTC requires 7 days.
IsolatedYes; Transformer isolated, 1,500V AC
PROFIBUSYes; Via CM DP module
As clientYes
As serverYes
SupportedYes
Backup time7 d
Memory size12 kbyte; Program memory
AutocrossingYes
Inputs, max.128 byte; Per device
Outputs, max.128 byte; Per device
Updating time4 ms; The minimum value of the update time also depends on the communication component set for PROFINET IO, on the number of IO devices and the quantity of configured user data.
For signal "0"I0.0 to I0.3 < 1 V DC; I0.4 to I2.7 < 5 V DC
For signal "1"I0.0 to I0.3 > 4V; I0.4 to I2.7 > 15V
PID controllerYes; PID closed-loop control function: Continuous controller outputs, binary controller outputs, automatic/manual mode, max. 8 loops
Shielded, max.500 m
AutonegotiationYes
ParameterizableYes; 6 Single phase: 4 HSCs at 200 kHz; 2 HSCs at 30 kHz 4 A/B phase: 2 HSCs at 100 kHz; 2 HSCs at 20 kHz
"0" to "1", max.3 µs; of the standard outputs, max. 3 µs; of the pulse outputs, max. (Q a.0 to Q a.3) 1 µs
"1" to "0", max.200 µs; of the standard outputs, max. 200 µs; of the pulse outputs, max. (Q a.0 to Q a.3) 50 µs
RJ 45 (Ethernet)Yes
Rated value24 V
Unshielded, max.150 m
Micro memory cardYes; microSDHC Card (optional)
Source (sink input)Yes
Number of counters6
On lamp load, max.5 W
Up to 40 °C, max.12
At "0" to "1", max.12.8 ms
At "0" to "1", min.0.2 ms
Programming packageSTEP 7 Micro/WIN SMART
For signal "1", min.20 V DC
For signal "1", typ.4 mA
Deviation per day, max.120 s; within 120s/month at 25 °C
Number of pulse outputs3
Number of relay outputs0
Status (control variable)Yes
Storage (transport, max.)1 080 hPa
Storage (transport, min.)660 hPa
Transmission rate, max.100 Mbit/s
For bit operations, typ.150 ns; / instruction
Number of digital inputs12
For word operations, typ.1.2 µs; / instruction
Number of digital outputs8
With resistive load, max.0.5 A
For signal "1" rated value0.5 A
Hardware clock (real-time)Yes
Of which High-Speed outputs3; 100 kHz Pulse Train Output
Memory available for user data8 kbyte
For backplane bus (5 v DC), max.1.4 A; max. 5 V DC for EM bus
For floating point arithmetic, typ.3.6 µs; / instruction
Permissible range, lower limit20.4 V
Permissible range, upper limit28.8 V
Number of connectable IO devices, max.8
Automatic detection of transmission rateYes; 10/100 Mbit/s
Limit class a, for use in industrial areasYes; EN 61000-6-4, interference emission: Intended for use in industrial areas.
Operation at 25 °C without condensation, max.95 %
Of the pulse outputs, with resistive load, max.100 kHz
Of which inputs usable for technological functions6; HSC (High Speed Counting)

Product details

I/O and memory capacity

The 6ES7288-1ST20-0AA1: The CPU handles 144 bytes of inputs and 144 bytes of outputs, mapped as 256 bits of digital I/O plus 56 words of analog I/O per device. Program memory is 12 KB, with DDR RAM and flash for retention. Forcing is supported, which helps during commissioning when you need to override a sensor without rewiring.

Communication and networking

Built-in PROFINET interface with autocrossing and autonegotiation, minimum update time 4 ms. RS-485 port runs up to 187.5 kbps for Modbus or point-to-point links. PROFIBUS is available via a CM DP module. The CPU can act as both Modbus client and server. Ethernet TCP/IP is native.

High-speed counters and PID

Six single-phase high-speed counters: four at 200 kHz, two at 30 kHz. For A/B phase quadrature encoders: two at 100 kHz, two at 20 kHz. The PID controller handles continuous or binary outputs across up to 8 loops with auto/manual mode — enough for a small process skid or conveyor zone.

Marked as current production. No successor or phase-out date has been published. CE marked; no UL or CSA listing appears in the record, so verify if your panel requires those marks.

Frequently asked questions

What are the key I/O specifications?

144 bytes each of inputs and outputs, mapped as 256 bits of digital I/O plus 56 words of analog I/O per device.

What programming languages does it support?

LAD (ladder), FBD (function block diagram), and STL (statement list).

What communication interfaces are built in?

PROFINET with autocrossing, RS-485 up to 187.5 kbps, and Ethernet TCP/IP. PROFIBUS requires an optional CM DP module.

What is the ambient temperature range?

-40 to 70 °C.

MPN
6ES7288-1ST20-0AA1