Skip to main content
Siemens 6ES7412-2XJ05-0AB0

Siemens 6ES7412-2XJ05-0AB0 CPU 412-2, 244 byte I/O, isolated

MPN 6ES7412-2XJ05-0AB0

Siemens S7-400 CPU 412-2, order code 6ES7412-2XJ05-0AB0, 244 byte inputs/outputs, isolated, cULus, CE, ATEX II 3G.

$1,492.25 – $2,539.00 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

6ES7412-2XJ05-0AB0 specifications
ParameterValue
Product typeSFB
InterfacePROFIBUS DP
Depth219 mm
Width25 mm
Height290 mm
Nesting levels7
Required slots1
Shortest clock pulse1.5 ms; 0.5 ms without use of SFC 126, 127

Product details

The Siemens 6ES7412-2XJ05-0AB0 is a CPU 412-2 module for the S7-400 rack. It provides 244 bytes each of process input and output image, isolated from the backplane, and supports a wide range of programming languages: CFC, FBD, LAD, SCL, STL, and GRAPH. Communication is via MPI, RS 485, and PROFIBUS DPV1. The module is 25 mm wide, 290 mm high, 219 mm deep, and operates from 0 °C to 60 °C.

The 244-byte input and output image determines how many discrete or analog channels the CPU can map without external expansion — enough for a medium-sized machine cell. Isolation means the logic side is galvanically separated from the I/O bus, protecting against ground loops and transient faults on field wiring. The ATEX II 3G Ex nA IIC T4 Gc certification permits installation in Zone 2 gas environments (non-sparking, T4 temperature class). cULus and CE mark cover North American and European regulatory acceptance.

No lifecycle status is on record for this order code. For compliance documentation, the CE mark and cULus listing are confirmed; RoHS/REACH declarations are not in the evidence and should be requested at time of order.

Integration constraints

The FM (function module) limit is stated as 'Limited by number of slots and number of connections' — this is not a hard count but a physical and connection-based ceiling. CP 440 and CP 441 PtP modules are similarly slot-limited. For PROFIBUS DP, the RDREC and WRREC SFBs are limited to 8 per interface, with a total of 32 across all external interfaces. The SFC 103 is limited to 1 per interface. No mixed operation of CP443-1 EX40 with EX41/EX20/GX20 is allowed; max 4 CPs in the central controller.

MPN
6ES7412-2XJ05-0AB0