Skip to main content
Siemens 6ES7414-3XM05-0AB0

Siemens 6ES7414-3XM05-0AB0 S7-400 CPU, 244 byte I/O, ATEX

MPN 6ES7414-3XM05-0AB0

Siemens S7-400 CPU 414-3 PN/DP, 6ES7414-3XM05-0AB0, 244 byte I/O, 16 connections, ATEX II 3G Ex nA IIC T4 Gc, cULus, CE.

$2,478.00 – $3,814.08 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

6ES7414-3XM05-0AB0 specifications
ParameterValue
Product typeSFB
Depth219 mm
Width50 mm
Height290 mm
Nesting levels7
Required slots2
Shortest clock pulse1 ms; 0.5 ms without use of SFC 126, 127

Product details

CPU 414-3 PN/DP — integrator constraints

The Siemens 6ES7414-3XM05-0AB0 is a CPU 414-3 PN/DP for the S7-400 rack, handling up to 244 bytes each of process-input and process-output image, with a maximum of 16 connections overall and a preset of 120 connections for the integrated PROFINET interface. Function blocks are limited per interface: SFB 52 (RDREC) and SFB 53 (WRREC) each allow 8 simultaneous instances per interface, capped at 32 across all external interfaces. SFC 59, SFC 58, SFC 55, SFC 13 each allow 8 per interface; SFC 103 allows 1 per interface; SFC 51 (RDSYSST) allows 8. Communication processors (CP) are limited by slot count and connection availability: CP 440 and CP 441 PtP modules are constrained by the number of slots and connections; for CP 443-1 EX40/EX41/EX20/GX20, a maximum of 4 can be used in the central controller, with no mixed operation of EX40 with the others.

Programming and configuration

The CPU supports CFC, FBD, LAD, SCL, STL, and GRAPH programming languages, and is configured via STEP 7. MPI is not supported on this CPU, so rely on PROFINET or the integrated RS 485 interface for programming and routing (routing is possible with the interface active). Forcing of I/O is supported. The CPU type is SFB (system function block). A GSD file is available from Siemens support for PROFIBUS DP integration.

Approvals and environmental limits

Carries ATEX II 3G Ex nA IIC T4 Gc certification for use in Zone 2 gas atmospheres, plus cULus and CE mark approvals. Operating temperature range is 0 °C to 60 °C. Physical dimensions: 50 mm wide, 290 mm high, 219 mm deep.

MPN
6ES7414-3XM05-0AB0