Siemens 6ES7510-1SK03-0AB0 — PLC Communication Modules

Siemens 6ES7510-1SK03-0AB0 S7-1500 CPU, 32kB I/O, PROFIsafe

MPN6ES7510-1SK03-0AB0
Active

Siemens SIMATIC S7-1500 CPU 1510SP-1 PN, 32 kB in/out process image, PROFINET IRT, PROFIsafe V2.4/V2.6, I²t 0.3 A²·s, 6ES7510-1SK03-0AB0.

$558.80Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

6ES7510-1SK03-0AB0 — Identification
ParameterValue
Configurable from STEP 7 TIA Portal versionV18 (FW V3.0); with older TIA Portal versions configurable as 6ES7510-1SJ01-0AB0
Firmware versionV3.0
Hardware functional status (FS)FS01
6ES7510-1SK03-0AB0 — Communication
ParameterValue
Transmission rate, max.12 Mbit/s
TCP/IP supportYes
I&M data supportYes; I&M0 to I&M3
Isochronous modeNo
6ES7510-1SK03-0AB0 — Electrical
ParameterValue
Rated value (DC)24 V
Permissible range, upper limit (DC)28.8 V
Permissible range, lower limit (DC)19.2 V
Current consumption, max.0.7 A
Power loss (typ.)6.5 W
Reverse polarity protectionYes
6ES7510-1SK03-0AB0 — I/O
ParameterValue
Input data area32 kbyte; All inputs are in the process image
Output data area32 kbyte; All outputs are in the process image
6ES7510-1SK03-0AB0 — Environmental
ParameterValue
Operating temperature, horizontal install, min.-30 °C; No condensation
Operating temperature, horizontal install, max.60 °C
Operating temperature, vertical install, max.50 °C
Operating temperature, vertical install, min.-30 °C; No condensation
6ES7510-1SK03-0AB0 — Mechanical
ParameterValue
Width100 mm
Height117 mm
Depth75 mm
TypeHardware clock

Product details

Safety and deterministic motion – the key ratings

The 6ES7510-1SK03-0AB0: PROFIsafe V2.4 / V2.6 is built in, so the CPU can run safety-oriented programs (F‑LAD, F‑FBD) without a separate safety module. For motion control, IRT combined with MRPD (Isochronous Real-Time with Media Redundancy for Planned Duplication) allows cycle times down to sub‑ms for coordinated drive groups. The I²t let‑through energy of 0.3 A²·s refers to the internal current‑limiting behaviour — useful for coordinating upstream protection devices; it is not a continuous rating. Multiple programming languages are available natively: LAD, FBD, STL, SCL, GRAPH, plus failsafe variants of the first two.

Network services and onboard functions

The CPU handles DCP (Discovery and Configuration Protocol) for automatic PROFINET device naming, DNS for resolving hostnames in industrial networks, DHCP, LLDP, SNMP, and HTTP/HTTPS with user‑definable pages. Modbus TCP is supported natively, and RS485 via a CM DP module. Two built‑in PID controllers cover continuous temperature loops (PID‑Temp) and valve positioning (PID‑3Step). The hardware clock is standard, and I&M data (I&M0‑I&M3) is present for asset tracking. Forcing is possible on non‑fail‑safe signals; fail‑safe channel forcing is not supported.

Frequently asked questions

What does the DCP (Yes) specification mean for commissioning?

DCP (Discovery and Configuration Protocol) is a PROFINET service that automatically assigns IP addresses and device names to the CPU and connected IO devices, streamlining initial network setup and reducing manual configuration errors.

What does the DNS (Yes) specification indicate?

DNS (Domain Name System) support allows the CPU to resolve hostnames on the industrial network, simplifying communication with remote devices like HMIs or SCADA servers by name instead of raw IP addresses.

MPN
6ES7510-1SK03-0AB0