Skip to main content
Siemens 6ES7512-1SK00-0AB0 — PLCs (Programmable Logic Controllers)

Siemens 6ES7512-1SK00-0AB0 CPU, 32 kB IO, PROFIsafe

MPN6ES7512-1SK00-0AB0

Siemens SIMATIC S7-1500 CPU, 6ES7512-1SK00-0AB0, 32 kbyte process image, supports PROFINET IRT, MRP, and PROFIsafe.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

6ES7512-1SK00-0AB0 — Processor & Memory
ParameterValue
Execution time, bit operations (typ.)48 ns
Execution time, word operations (typ.)58 ns
Execution time, floating-point arithmetic (typ.)307 ns
Size, max.16 kbyte
6ES7512-1SK00-0AB0 — I/O
ParameterValue
Input data area32 kbyte; All inputs are in the process image
Output data area32 kbyte; All outputs are in the process image
6ES7512-1SK00-0AB0 — Programming
ParameterValue
Programming language: FBDYes; incl. failsafe
Programming language: LADYes; incl. failsafe
Programming language: SCLYes
6ES7512-1SK00-0AB0 — Electrical
ParameterValue
Rated value (DC)24 V
Current consumption (rated)0.6 A
Permissible range, lower limit (DC)19.2 V
Permissible range, upper limit (DC)28.8 V
Power loss (typ.)5.6 W
6ES7512-1SK00-0AB0 — Mechanical
ParameterValue
Width100 mm
Height117 mm
Depth75 mm
Weight (approx.)310 g
6ES7512-1SK00-0AB0 — Environmental
ParameterValue
Operating temperature, min. (horizontal mounting)0 °C
Operating temperature, max. (horizontal mounting)60 °C

Product details

On a zoned conveyor line

The 6ES7512-1SK00-0AB0: This CPU drops right into a standard 24 V DC control panel. The MRP ring handles cable redundancy: if a trunk gets cut, the ring recovers and the line keeps running – no jam because a single cable failed. IRT keeps the PROFINET cycle deterministic, so zone-to-zone handoffs stay tight even with 50 devices on the ring. And with PROFIsafe, you can connect emergency stops and door interlocks straight to the CPU; the failsafe FBD blocks handle the logic without a separate safety PLC. DCP support means you can name each device on the network from the engineering tool – no manual IP keying on the line. The 32 kB process image handles a pile of photoeyes and motor-roller zones without reaching for an expansion rack.

Frequently asked questions

Does 6ES7512-1SK00-0AB0 support DCP?

Yes, DCP (Device Configuration Protocol) is supported, used for PROFINET device naming and IP assignment.

What programming languages are supported, especially for safety?

FBD and LAD are supported, both including failsafe blocks for safety logic. Also SCL, STL, and GRAPH.

MPN
6ES7512-1SK00-0AB0