Siemens 6GT2815-0BN10 — RFID & Auto-ID

Siemens 6GT2815-0BN10 SIMATIC RF600 Coaxial Cable, 10 m, 50

MPN6GT2815-0BN10
Active

Siemens SIMATIC RF600 connecting cable, coaxial, LMR-195, 10 m, 50 Ω, pre-assembled R-TNC (female) both ends, IP65, PE dielectric, CMR/FT4 flame rated.

$81.28Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

6GT2815-0BN10 — RF / Air interface
ParameterValue
Power, max.1000 V
6GT2815-0BN10 — Communication / Electrical
ParameterValue
Electrical connector typeR-TNC (female, straight) / R-TNC (female, straight)
Number of electrical connections2
6GT2815-0BN10 — Mechanical
ParameterValue
Cable length10 m
Cable sheath colorBlack
6GT2815-0BN10 — Environmental
ParameterValue
Operating temperature range-40 ... +85 °C
Installation temperature range-40 ... +80 °C
Storage temperature range-70 ... +85 °C
Transport temperature range-40 ... +85 °C

Product details

The Siemens 6GT2815-0BN10 is a pre-assembled coaxial cable from the SIMATIC RF600 family, designed as a plug-in connection between an RF600 reader and a UHF antenna. It carries a characteristic impedance of 50 Ω, which is the standard for UHF RFID antenna feeds — mismatching this value introduces return loss and reduces read range. The cable is terminated with R-TNC (female, straight) connectors on both ends, so it drops directly into the reader and antenna ports without field termination.

Maximum voltage rating is 1000 V, which is the insulation rating of the cable and connectors. Attenuation is specified at 0.365 dB/m at 900 MHz, which is the center of the UHF RFID band (860–960 MHz). Over the 10 m length, that works out to roughly 3.65 dB of loss — about half the power is dissipated in the cable. For a typical reader output of 30 dBm, the antenna sees about 26.35 dBm. If your installation requires a longer cable run, factor this loss into the link budget; the reader's output power may need adjustment to stay within regulatory limits. The cable is designated LMR-195, a low-loss 50 Ω coaxial cable with a solid copper inner conductor and a braided shield of tin-plated copper wires. The minimum bend radius with a single bend is 12.7 mm; with repeated flexing, keep bends above 50.8 mm to avoid work-hardening the braid. Flame rating is CMR (Communications Riser) per UL/NEC and FT4 per CSA, but only for the cable without the plug — the assembled connectors may have a different listing. For plenum-rated installations, verify the connector's own flame rating separately.

Frequently asked questions

What is the maximum voltage rating?

The cable assembly is rated for a maximum voltage of 1000 V. This is the insulation rating, not the RFID system operating voltage.

What is the characteristic impedance?

50 Ω, which is the standard impedance for UHF antenna feeds. Using a cable with a different impedance will cause mismatch loss.

MPN
6GT2815-0BN10