Specifications

6GT2891-4JN10 — RF / Air interface
ParameterValue
Power, max.300 V
6GT2891-4JN10 — Communication / Electrical
ParameterValue
Electrical connector typeM12 (male, 8 pin, straight) / M12 (female, 8 pin, angled)
Number of electrical connections2
6GT2891-4JN10 — Mechanical
ParameterValue
Cable length10 m
Cable sheath colorBlack
Silicone-freeYes
6GT2891-4JN10 — Environmental
ParameterValue
Operating temperature range-30 ... +80 °C
Installation temperature range-30 ... +80 °C
Storage temperature range-30 ... +80 °C
Transport temperature range-30 ... +80 °C

Product details

The Siemens 6GT2891-4JN10 is a pre-assembled SIMATIC RF MV plug-in cable, 10 m long, designed to connect an RFID reader to a communication module such as the ASM 456, RF160C, RF170C, or RF18XC. It is a 6-core cable with a braided shield of tin-plated copper wires, terminated with an M12 8-pin male straight connector on one end and an M12 8-pin female angled connector on the other. The PUR jacket and trailing-capable construction make it suited for dynamic applications on moving machine parts or cable carriers.

Rated for 3 million bending cycles with a minimum continuous-bend radius of 75 mm, this cable is built for high-flex applications like gantry robots or linear axes. The minimum single-bend radius is 21.6 mm, and the multiple-bend minimum is 43 mm — respect these during routing to avoid internal conductor fatigue. Maximum tensile load is 200 N, which sets the pull-force limit during installation or when the cable is dragged through a cable carrier. The cable is rated for operation, storage, transport, and installation across the full -30 to +80 °C range, so no special temperature derating is needed for typical factory-floor environments. It is resistant to grease, mineral oil, and UV radiation, and its flame behavior meets IEC 60332-1-2. The jacket is black PVC, silicon-free, but not halogen-free — note that for any low-smoke, zero-halogen (LSZH) zone requirements.

Electrical characteristics and approvals

Maximum rated voltage is 300 V. Loop resistance is specified at a maximum of 160 mΩ/m, and insulation resistance coefficient is 20 GΩ·m — both figures you'd use to verify signal integrity over the full 10 m run, especially for RS-485 or similar differential signals. The cable carries EAC approval for the Eurasian Economic Union customs zone. The wire insulation follows DIN 47100 color coding, and the outer diameter has a symmetrical tolerance of 0.2 mm, which matters for gland fit.

Frequently asked questions

What is the maximum voltage rating of this cable?

The cable is rated for a maximum of 300 V.

What approvals does this cable carry?

It carries EAC approval for the Eurasian Economic Union. It is also flame-resistant per IEC 60332-1-2.

What is the cable's resistance to chemicals and environmental factors?

The PUR jacket is resistant to grease, mineral oil, and UV radiation. The cable is also silicon-free.

What is the bend radius and flex life for this cable?

It is rated for 3 million bending cycles with a minimum continuous-bend radius of 75 mm. The minimum single-bend radius is 21.6 mm, and the multiple-bend minimum is 43 mm.