Skip to main content
Siemens 6SL3200-6AM13-1AH0 — AC Drive (VFD) 480V

Siemens 6SL3200-6AM13-1AH0 G120P Filter A, 1.1 kW, IP55

MPN6SL3200-6AM13-1AH0
Active

Siemens SINAMICS G120P, variable speed drive, 1.1 kW, 3.1 A, 400 V, IP55, Filter A, 50/60 Hz, EN 61800-3.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

6SL3200-6AM13-1AH0 — Mechanical & Cooling
ParameterValue
Degree of protection (IP)IP55
6SL3200-6AM13-1AH0 — Other specifications
ParameterValue
StandardEN 61800-3
Frequency50/60 Hz
Data sheetN5111
Filter typeA
Power output1.1 kW
Weight5.01 kg
ProtocolModbus/RTU; RS485/USS; BACnet MS/TP; PROFIBUS (optional); PROFINET (optional); CANopen (optional)
Output current3.1 A
Operating voltage400 V
Overload capacity110% for 57 sec. and 150% for 3 sec. every 300 sec.
Product conformityCE; RCM; EAC
Dimensions (W x h x d)154 x 460 x 249 mm

Product details

Drive stage and enclosure

The Siemens 6SL3200-6AM13-1AH0 is a SINAMICS G120P variable speed drive rated for 1.1 kW output power at 3.1 A from a 400 V supply. The IP55 enclosure means it handles dust and water jets — fine for standalone mounting in a washdown area or a non-conditioned machine cabinet without a separate enclosure. Filter A is built in, so conducted emissions on the line side stay within EN 61800-3 limits for a typical industrial environment; you don't need an external EMC filter for most installations.

Fieldbus flexibility

Onboard communication covers Modbus RTU, RS485/USS, and BACnet MS/TP natively. If your line runs PROFIBUS, PROFINET, or CANopen, those are available as optional add-ons — order the option module to match your backbone. No need to swap the base drive for a different variant.

Overload capacity and duty cycle

The drive delivers 110 % overload for 57 seconds and 150 % for 3 seconds, every 300 seconds. That 150 % burst handles short-duration torque peaks — think a conveyor starting under load or a crusher clearing a jam — without tripping. The 57-second window at 110 % covers longer acceleration ramps for high-inertia loads like fans or centrifuges.

Frequently asked questions

What fieldbus protocols does this drive support?

Modbus RTU, RS485/USS, and BACnet MS/TP are onboard. PROFIBUS, PROFINET, and CANopen are available as optional modules.

What is the overload capacity of the 6SL3200-6AM13-1AH0?

110 % for 57 seconds and 150 % for 3 seconds, with a 300-second cycle time between overload events.

Where can I buy the 6SL3200-6AM13-1AH0?

It is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

MPN
6SL3200-6AM13-1AH0