Skip to main content
Siemens 6SL3200-6AM13-1BH0 — AC Drive (VFD) 480V

Siemens 6SL3200-6AM13-1BH0 G120P VFD, 1.1 kW, IP55, Filter B

MPN6SL3200-6AM13-1BH0
Active

Siemens SINAMICS G120P, FSA, IP55, Filter B, 1.1 kW variable speed drive, order code 6SL3200-6AM13-1BH0.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

6SL3200-6AM13-1BH0 — Mechanical & Cooling
ParameterValue
Degree of protection (IP)IP55

Product details

The Siemens 6SL3200-6AM13-1BH0 is a SINAMICS G120P variable speed drive in frame size FSA, rated for 1.1 kW power output at 400 V operating voltage and delivering 3.1 A output current. It carries an integrated Filter B, making it suitable for environments where conducted emissions need to be suppressed per EN 61800-3 — that standard covers power drive systems and their EMC limits, so this unit is pre-configured for installations where line-side filtering is required without an external box.

The 1.1 kW power output at 3.1 A is sized for a 400 V three-phase supply. Output frequency ceiling is 550 Hz. Overload capacity is 110% for 57 seconds and 150% for 3 seconds, repeating every 300 seconds. That 150% burst handles short-duration torque spikes — a jammed conveyor or a fan restart against a closed damper — without tripping. The 57-second window at 110% covers moderate overloads like a pump cycling against a partially closed valve. IP55 degree of protection means the drive is dust-protected and can withstand water jets from any direction. This unit is built for standalone mounting in washdown areas or outdoor cabinets — no need for a separate enclosure in most indoor industrial environments, though direct hose-down still requires the cable glands to be properly sealed.

The drive supports Modbus/RTU, RS485/USS, and BACnet MS/TP natively, with optional PROFIBUS, PROFINET, and CANopen via add-on modules. For a building-automation or HVAC application, the onboard BACnet MS/TP is the direct fit — it talks to a BMS without a gateway. For a factory-floor line, the optional PROFINET card is the usual choice. It carries 4 analog inputs, 2 analog outputs, and 6 digital inputs. That is enough for a basic PID loop (one analog input for feedback, one analog output for speed reference) plus a handful of start/stop and fault-reset signals. No analog expansion is needed for simple pressure or flow control.

It is a mature product in the SINAMICS G120P line.

The drive carries CE, EAC, and RCM conformity marks. The EN 61800-3 standard covers EMC performance for power drive systems.

Frequently asked questions

What is the EN 61800-3 standard listed on this drive?

EN 61800-3 is the EMC standard for power drive systems. It defines emission and immunity limits for adjustable-speed drives. The integrated Filter B on this unit addresses the conducted emission requirements of that standard.