Skip to main content
Siemens 6SL3210-1KE13-2UP1 — AC Drives (VFD)

Siemens 6SL3210-1KE13-2UP1 SINAMICS G120C Drive, 1.1kW, 380-

MPN6SL3210-1KE13-2UP1

Siemens SINAMICS G120C drive, 6SL3210-1KE13-2UP1, 1.1 kW rated power, 380-480 V 3AC, 150% overload for 3 s, PROFIBUS DP, Safe-Torque-Off, IP20, FSA size.

$1,208.72Ref. price · indicative, final on quote
StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Mechanical

6SL3210-1KE13-2UP1 — Mechanical
ParameterValue
Weight1.03 kgs

Product details

Drive selection memo

The Siemens 6SL3210-1KE13-2UP1 is a SINAMICS G120C compact drive rated for 1.1 kW output power with 150% overload capability for 3 seconds — enough headroom to handle short-duration load spikes on a conveyor or pump without tripping. Input accepts 380-480 V 3-phase AC at 47-63 Hz, unfiltered, so it lands on standard European and North American line voltages without an external line reactor for basic installations. The drive integrates PROFIBUS DP as its native fieldbus, meaning it drops into a Siemens S7-300/400 or ET 200 network without an add-on communication module. Safe-Torque-Off (STO) is built in — no separate safety relay needed for the stop function. That saves a DIN-rail slot and reduces wiring in a panel where the safety circuit demands a controlled disconnect of drive torque. The I/O complement — 6 digital inputs, 2 digital outputs, 1 analog input, 1 analog output — covers basic feedback and control for a single-axis application without an expansion module.

Panel fit and integration

The drive ships in FSA frame size: 196 x 73 x 203 mm (HxWxD). That 73 mm width fits a standard 600 mm deep enclosure with room for gland plates and cable ducts. IP20 / UL Open Type means it is intended for a clean, dry electrical enclosure — not for washdown or outdoor mounting. External 24 V supply required for the control logic; the drive does not generate its own control voltage.

Frequently asked questions

What is the rated power and overload capability of this drive?

Rated power is 1.1 kW with 150% overload for 3 seconds. That 150% peak handles short-duration load spikes typical of starting a loaded conveyor or pump.

What fieldbus protocol does this drive support?

PROFIBUS DP is integrated as the native fieldbus. No add-on communication module is required for connection to a PROFIBUS DP network.

Does this drive include Safe-Torque-Off?

Yes, Safe-Torque-Off (STO) is integrated. This eliminates the need for a separate safety relay for the torque-disconnect function in the safety circuit.

Where can I buy 6SL3210-1KE13-2UP1 and how is it quoted?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

MPN