Skip to main content
Siemens 6SL3220-1YD44-0UB0 — AC Drives (VFD)

Siemens 6SL3220-1YD44-0UB0 SINAMICS G120XA VFD, 90 kW, 164 A

MPN6SL3220-1YD44-0UB0

Siemens SINAMICS G120XA AC drive, 6SL3220-1YD44-0UB0, 90 kW at 400 V, 164 A rated current (LO), 3-phase 380-440 VAC input, IP20, 61 kg.

$2,813.00Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

6SL3220-1YD44-0UB0 — Identification
ParameterValue
Product typeSINAMICS G120XA
6SL3220-1YD44-0UB0 — Electrical
ParameterValue
Line voltage380 ... 440 V +10 % -20 %
Line frequency47 ... 63 Hz
Number of phases3 AC

Product details

The 6SL3220-1YD44-0UB0 is a SINAMICS G120XA AC drive rated 90 kW at 400 V in low overload (LO) duty, drawing 164 A continuous. For higher-breakaway loads, the max output current of 181 A provides headroom for short-duration acceleration peaks. The 0–550 Hz output range in V/f control covers high-speed spindle applications; vector control tops out at 240 Hz, which suits most servo-class positioning on conveyors or winders.

Efficiency and thermal budget — 0.98 and 2.16 kW loss

At 0.98 efficiency, the drive wastes 2.16 kW as heat at full load. That loss figure drives the enclosure ventilation requirement — a panel with this drive needs forced airflow or a heat exchanger to keep ambient below the 40 °C derating threshold typical for G120XA frames. The power factor range of 0.75–0.93 (cos φ 0.99 offset) means the input harmonics are moderate for a 6-pulse drive; if the plant has strict THD limits, a line reactor or active filter on the supply side is worth budgeting.

Mature lifecycle — what that means for a BOM line

For a tail-spend buyer consolidating onto a preferred catalog, this is a stable line item — the SINAMICS G120XA series has been on the market long enough that spares and documentation are settled.

Physical fit — 61 kg and panel integration

The 4 kHz pulse frequency is the factory default; raising it quiets motor whine but derates output current. For a pump application where acoustic noise is secondary, leaving it at 4 kHz keeps the full 164 A available.

Frequently asked questions

What is the output frequency range for vector control on this drive?

The vector control output frequency range is 0–240 Hz. For V/f control, the range extends to 0–550 Hz, which covers high-speed spindle applications beyond what vector mode supports.

What compliance documentation is available for this Siemens drive?

The SINAMICS G120XA series carries CE and UL/cUL markings as standard. RoHS and REACH declarations are part of the Siemens documentation package available at time of order. Specific certification numbers are confirmed with the shipment documentation.

MPN