Skip to main content
Siemens 6SL3220-3YC30-0UB0 — AC Drives (VFD)

Siemens 6SL3220-3YC30-0UB0 SINAMICS G120X VFD, 18.5 kW, IP20

MPN6SL3220-3YC30-0UB0
Active

Siemens SINAMICS G120X AC Drive, 6SL3220-3YC30-0UB0, 18.5 kW, 200-240 V 3AC, IP20, frame size FSD, with Intelligent Operator Panel, MODBUS RTU and BACnet MS/TP.

StockContact for availability
Lead timeIn Stock wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

6SL3220-3YC30-0UB0 — Identification
ParameterValue
Product familyOrdering Data Overview

Other specifications

6SL3220-3YC30-0UB0 — Other specifications
ParameterValue
Group codeR220
Product group4R52
Product classB: return restricted, please contact your Siemens partner/contact
Export control regulationsAL : N / ECCN : N
Compliance with the substance restrictions according to RoHS directiveSince: 01-07-06

Product details

Duty-cycle margin for pump and fan loads

The 6SL3220-3YC30-0UB0 is rated 18.5 kW with a 110% overload capability for 60 seconds and 100% continuous for 240 seconds. That overload profile matches variable-torque loads like centrifugal pumps and fans where the peak demand is during start-up or a momentary process upset, not sustained. The input accepts 200-240 V 3-phase AC, +10/-20%, at 47-63 Hz. On a 208 V supply the drive still delivers full rated power; on a 200 V rail with -20% tolerance (160 V) the DC bus drops and output current must be derated — budget a 10-15% power reduction if the line is known weak.

Panel integration and fieldbus wiring

Frame size FSD with IP20 / UL open type — this is a panel-mount drive, not a standalone enclosure. The painting class 3C2 means the sheet metal resists moderate corrosive atmospheres (condensing humidity, salt mist) but the IP20 rating requires the drive to sit inside a cabinet that provides the environmental seal. Fieldbus is integrated: MODBUS RTU and BACnet MS/TP on the same RS-485 port. For building automation the BACnet stack eliminates the gateway; for industrial lines the MODBUS RTU maps the drive parameters directly into a PLC register map. No IO expansion module is included — the IOP handles local commissioning and the fieldbus handles remote I/O.

Compliance and export documentation

RoHS compliant since 2006-07-01. REACH Article 33 data is available per the current candidate list — the drive carries the documentation needed for EU substance compliance filings. Export Control Regulations: AL: N / ECCN: N. No license barrier for most commercial destinations; the drive ships under NLR (No License Required) classification.

Frequently asked questions

What compliance documentation does Siemens provide for 6SL3220-3YC30-0UB0?

RoHS compliance since 2006-07-01 and REACH Article 33 duty-to-inform data are available.

MPN
6SL3220-3YC30-0UB0