Skip to main content
Siemens 7ME6810-4HC31-1CA0 — Flow Meters

Siemens 7ME6810-4HC31-1CA0 MAG 8000 Flowmeter, DN 150

MPN7ME6810-4HC31-1CA0

Siemens SITRANS FM MAG 8000 battery-operated electromagnetic flowmeter, DN 150 (6 inches), EN 1092-1 PN 16, EPDM liner, Hastelloy electrodes, calibration certificate 0.4% of rate ± 2 mm/s, IrDA interface, PED compliant.

$5,075.00Ref. price · indicative, final on quote
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

7ME6810-4HC31-1CA0 key specifications
ParameterValue
TypeBattery-operated electromagnetic flowmeter
Power supplyInternal battery (battery not included)
ProtocolStandard IrDA interface (no additional communication)
Weight32.000 Kg
Liner materialEPDM
Shipping weight33 Kg
Electrode materialHastelloy
Flange standardEN 1092-1, PN 16
Pressure equipment directive (PED) complianceYes
CoatingCorrosion-resistant, Category C4
Displaym³ based, 50 Hz filter
DiameterDN 150 (6 inches)

All specifications

7ME6810-4HC31-1CA0 additional specifications
ParameterValue
ApplicationVolume flow measurement of conductive liquids and water
CalibrationStandard, with certificate, max. 0.4% of rate +/- 2mm/s
ManufacturerSiemens
Suitable forAbstraction, distribution network, revenue metering, and irrigation
Region versionEurope
Remote versionBasic, 10m mounted sensor cables with plugs
Flow rate629 m³/h
Estimated lead time6 - 8 Weeks

Product details

Application fit for water and revenue metering

The Siemens 7ME6810-4HC31-1CA0 is a battery-operated electromagnetic flowmeter from the SITRANS FM MAG 8000 series, designed for volume flow measurement of conductive liquids and water in abstraction, distribution networks, revenue metering, and irrigation. The DN 150 (6-inch) flanged body mates to EN 1092-1 PN 16 pipework, and the EPDM liner handles potable water and general aqueous media up to the liner's temperature limits.

Accuracy and calibration traceability

Calibration is standard with certificate, achieving a maximum error of 0.4% of rate ± 2 mm/s — this is the accuracy floor for custody-transfer-adjacent metering, not just a full-scale spec. The Hastelloy electrodes resist corrosion in aggressive conductive liquids, and the corrosion-resistant coating (Category C4) protects the body in outdoor or humid environments.

Power, communication, and installation constraints

Powered by an internal battery (not included), this flowmeter operates without external mains — critical for remote abstraction points or distribution nodes where line power is absent. Communication is via a standard IrDA interface only; no additional protocol modules are fitted, so data retrieval requires line-of-sight infrared access. The basic remote version includes 10 m mounted sensor cables with plugs, simplifying installation when the transmitter is mounted away from the sensor.

The 7ME6810-4HC31-1CA0 is a Europe-region variant (EN flange, PED compliance), so confirm regional code compatibility for non-European installations.

MPN