Skip to main content
Siemens 7SJ6211-5EB02-1FG0/FF,,F — General Purpose Relays

Siemens 7SJ6211-5EB02-1FG0/FF,,F SIPROTEC 4 7SJ62 Protection

MPN7SJ6211-5EB02-1FG0/FF,,F

Siemens SIPROTEC 4 7SJ62 multifunction protection relay, 7SJ6211-5EB02-1FG0/FF,F, designation FG, for panel flush mounting, screw-type terminals, 8 BI, 8 BO, DC 110-250 V / AC 115-230 V aux supply.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

7SJ6211-5EB02-1FG0/FF,,F — Specifications
ParameterValue
DesignationFG
Product typeSIPROTEC 4 7SJ62 Multifunction Protection Relay
Unit versionE = For panel flush mounting, screw-type terminal (direct connection/ring-type cable lugs)
Housing, inputs, outputs1 = Housing ?19”, 4 line text display, 3 x U, 4 x I, 8 BI, 8 BO, 1 live status-contact
Measuring (fault recording)1 = Fault recording
System interface (Port b)0 = No system interface
Service interface (Port c)2 = DIGSI 4/modem/RTD-box, electrical RS485
ARC, fault locator, synchro-check0 = Without
Measuring inputs (3 x v / 4 x v, 4 x i)1 = Iph = 1 A, Ie = 1 A (min. = 0.05 A) Position 15 only with A, C, E, G
Rated auxiliary voltage (power supply, indication voltage)5 = DC 110 to 250 V, AC 115 to 230 V, threshold binary input DC 88 V
Region-specific default settings (function versions and language settings)B = Region World, 50/60 Hz, IEC/ANSI, language: English (GB), selectable

Product details

The 7SJ6211-5EB02-1FG0/FF,,F: The 7SJ6211-5EB02-1FG0/FF,F is a Siemens SIPROTEC 4 7SJ62 multifunction protection relay — a 19" rack-mount unit with a 4-line text display, three voltage and four current measurement inputs, eight binary inputs, eight binary outputs, and one live status contact. It is configured for panel flush mounting using screw-type terminals for direct connection or ring-type cable lugs. Rated auxiliary voltage covers DC 110 to 250 V and AC 115 to 230 V, with a binary input threshold of DC 88 V. The relay ships with worldwide default settings (50/60 Hz, IEC/ANSI) and English-language firmware, selectable via DIGSI 4.

The 8 BI / 8 BO count defines the I/O budget for feeder protection schemes. The 3 voltage and 4 current inputs support standard three-phase plus residual current measurement, with phase current rated 1 A and earth current 1 A (minimum 0.05 A). The 4-line display is enough for local metering and event logs without an external HMI. The service interface (Port C) is electrical RS485 for DIGSI 4, modem, or RTD-box connection. No system interface (Port B) is fitted, so this variant communicates only via the serial service port — no Profibus or Ethernet on board. The fault recording option is included. The auxiliary voltage range (DC 110-250 V / AC 115-230 V) is the standard wide-range supply for substation control voltages; the DC 88 V binary input threshold ensures reliable pickup on a nominal 110 VDC battery system with typical voltage drop.

Frequently asked questions

What is the auxiliary voltage requirement?

The relay accepts DC 110 to 250 V and AC 115 to 230 V. The binary input threshold is DC 88 V.

Does this relay include a system interface (fieldbus)?

No. The system interface (Port B) is omitted. Only the service interface (Port C) is fitted — electrical RS485 for DIGSI 4, modem, or RTD-box.

MPN
7SJ6211-5EB02-1FG0/FF,,F