Siemens 7SX8000-3AA50-1CA0-ZP15

MPN7SX8000-3AA50-1CA0-ZP15

7SX800 universal protection device; contains 150 function points; BI: 4; BO: 5 (4 fast, 1 life); I: 4 (4 x protection); U: 4 (standard); housing: 1/6 x 19''; 8 LEDs; 9 function keys; Ethernet: optical; serial interface; operation panel: integrated; display type: color display; front design: standard; auxiliary voltage: 24 V - 250 V DC, 115 V - 230 V AC

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jun 2026

Specifications

7SX8000-3AA50-1CA0-ZP15 key specifications
ParameterValue
Type of voltage (Of the supply voltage)AC/DC
Supply voltage (at AC)115 ... 230 V
Supply voltage (at DC)24 ... 250 V
Number of voltage inputs (Maximum)4
Voltage-Based protection functionsone-time 40 function points for voltage based function package
Voltage variation protection (ANSI 59R/27R)Yes
Measuring voltage failure detection (ANSI 60FL)Yes
Power quality assessment function (Voltage unbalance)20 function points
Reactive power-low-voltage protection (Q-U protection)Yes
Voltage-dependent overcurrent-time protection (ANSI 51V)Yes
Inrush current detectionYes
Number of current inputs (Maximum)4

All specifications

7SX8000-3AA50-1CA0-ZP15 additional specifications
ParameterValue
Sensitive ground current protection (ANSI 50Ns)No
Current unbalance protection for capacitor banks 1-phase (ANSI 60C)Yes
Power factor (ANSI 55)Yes
Reverse power protection (ANSI 32R)Yes
Forward power supervision (ANSI 32F)Yes
Directional power monitoring (ANSI 32)Yes
Power quality assessment function (Total demand distortion)10 function points
Frequency protection (ANSI 81)Yes
Automatic frequency relief (ANSI 81U)Yes
Frequency variation protection (ANSI 81R)Yes
Three-Pole trippingYes
Phase-rotation supervision (ANSI 47)Yes
Peak overvoltage protection, 3-Phase for capacitorsYes
Directional overcurrent-time protection, phases (ANSI 67)Yes
Modbus TCPYes
Communication (Ethernet)one-time 50 function points for ethernet communication package
Protocol (is supported, HSR)Yes
Protocol (is supported, PRP)Yes
Protocol (is supported, RSTP)Yes
Protocol / is supported / DNP 3, TCPNo
Protocol (is supported, PROFINET IO)No
Protocol / is supported / DNP 3, serialNo
Protocol / is supported / IEC 60870-5-103No
Protocol / is supported / IEC 60870-5-104No
Protocol (is supported, modbus RTU slave)No
Product feature (Plug-In terminal blocks)Yes
Product component (with RTD unit connection)Yes
Ambient temperature (During operation, maximum)55 °C
Depth229 mm
Width74 mm
Height266 mm
IEC 61850-8-1Yes
ControlYes
MonitoringYes
Number of LEDs8
Motor protection5 function points per motor protection function
Circuit breaker testYes
Switching statisticsYes
Vector step protectionYes
Synchrocheck (ANSI 25)Yes
Number of function keys9
Fault locator (ANSI FL)Yes
External trip initiationYes
Number of parameter sets8
Parameter set switchoverYes
Circuit breaker monitoringYes
Closing lock-out (ANSI 86)Yes
Reclosing lockout (ANSI 66)Yes
With blocked rotor (ANSI 14)Yes
Automatic reclosing (ANSI 79)Yes
Product feature (Logic editor)Yes
Switch on to fault (ANSI SOTF)Yes
Unbalance protection (ANSI 46)Yes
Load step protection (ANSI 50L)Yes
Overvoltage protection (ANSI 59)Yes
Temperature monitoring (ANSI 38)Yes
Undercurrent protection (ANSI 37)Yes
Undervoltage protection (ANSI 27)Yes
Number of digital inputs (Maximum)4
Blocked rotor monitoring (ANSI 48)Yes
Overexcitation protection (ANSI 24)Yes
Intermittent Ground-Fault protectionYes
Trip-circuit supervision (ANSI 74TC)Yes
Thermal overload protection (ANSI 49)Yes
Synchro pointer measurement (ANSI PMU)No
Bearing temperature monitoring (ANSI 38)Yes
Dynamic response value changeover (ANSI 51C)Yes
Fault recording for analog and digital signalsYes
Circuit breaker failure protection (ANSI 50BF)Yes
Directional ground fault protection (ANSI 67N)Yes
Circuit breaker backfire monitoring (ANSI 50RS)Yes
Ground fault differential protection (ANSI 87N)Yes
Directional intermittent Ground-Fault protectionYes
Definite overcurrent-time protection (ANSI 50/50N)Yes
Dependent overcurrent-time protection (ANSI 51/51N)Yes
Overvoltage protection zero-sequence system (ANSI 59N)Yes
Overvoltage protection negative-sequence system (ANSI 47)Yes
Overcurrent-time protection negative sequence system (ANSI 46)Yes
Product function (supports further ethernet services on ethernet modules)Yes
Directional sensitive ground-fault detection for resonant-grounded systems and isolated systems (ANSI 67Ns)No
Ground-fault wiper function, for transient and static ground faults in resonant-grounded systems and isolated systems (ANSI 67Ns)No
Sensitive ground-fault detection for resonant-grounded systems and isolated systems according to the admittance method (ANSI 67Ns)No
Sensitive ground-fault detection for resonant-grounded systems and isolated systems via pointer measurement with 3rd or 5th harmonic (ANSI 67Ns)No
MPN
7SX8000-3AA50-1CA0-ZP15