Omron CJ1W-TS561

Omron CJ1W-TS561 Analog Input Module, 6 Ch, CJ1W

MPN CJ1W-TS561
End of Life

Omron CJ1W, CJ1W series Input Module, 6 analog inputs, screw terminal, DIN rail mount, operating 0°C~55°C, order code CJ1W-TS561.

$375.48 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

CJ1W-TS561 specifications
ParameterValue
SeriesCJ1 W
Product typeInput Module
MountingDIN Rail
Temp operating max55 °C
Temp operating min0 °C
Weight0.331 lb (150.14 g)
PackageBulk

Product details

The Omron CJ1W-TS561 is an analog input module on the CJ1W I/O family — six analog inputs landed on screw terminals, slotted into a CJ Series rack next to the CPU and the rest of the local I/O. It carries the same DIN-rail footprint and backplane connector as the rest of the CJ1W lineup, so the mechanical and bus side of the install follows family practice rather than a one-off cutout.

What the key envelope means in the panel

Operating range is 0 °C to 55 °C, which is the standard control-room envelope — the module does not need a cabinet heater or a cold-weather spec derate for a typical indoor cell, but anything outside that band is not on the menu without external conditioning. Termination is screw, not spring-cage or MIL connector, so the wireman is terminating with a standard blade driver rather than pushing ferruled leads into a cage — worth flagging on the wiring diagram if the rest of the rack has migrated to push-in.

Sourcing posture and lifecycle flag

The evidence lists the lifecycle flag but no successor order code; sourcing a like-for-like second source is an integrator step, not a datasheet statement.

Integration checklist for the controls integrator

Slot it on the CJ1W local rack next to the CPU; the analog count is six, so any tag database that assumed two channels (a PTS15 baseline) needs to be re-sized before the rack is powered up. Confirm the analog signal class — voltage, current, or TC/RTD — against the field wiring before termination; the listing names the module as analog input but does not carry the signal-class detail, which is a question for the supplier rather than a guess on the bench. Operating envelope of 0 °C to 55 °C is the standard indoor control-cabinet window; no special derating curve is published in this evidence, so the integrator should follow the family derating note rather than a per-module curve.