Skip to main content
Omron E5CC-QQ3D5M-003

Omron E5CC-QQ3D5M-003 Temperature Controller, 24VAC/DC

MPN E5CC-QQ3D5M-003
Active

Omron E5CC series process/temperature controller, 24VAC/DC supply, relay and voltage (SSR) outputs, RS-485 Modbus RTU, IP66 front panel, 45 mm square cutout.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

E5CC-QQ3D5M-003 specifications
ParameterValue
SeriesE5CC
Output signalRelay (3), Voltage (External SSR) (2)
Supply voltage24 VAC/DC
IP ratingIP66
ProtocolRS-485 (CompoWay/F, Modbus)
MountingPanel Mount
Temp operating max55 °C
Temp operating min-10 °C
Weight0.265 lb (120.2 g)
PackageBox
Control methodOn/Off, Proportional (PID)

Product details

Panel fit and field wiring

The Omron E5CC-QQ3D5M-003 is a 1/16 DIN process and temperature controller that drops into a standard 45.00 mm square panel cutout and secures with the included mounting bracket — no adapter plate needed for a fresh panel or a retrofit into an existing E5CC footprint. Screw-terminal connections are used. The front bezel is IP66-rated.

What the outputs and inputs actually do

Three relay outputs drive the primary control loop, alarm, or event functions — rated for switching contactors, solenoid valves, or indicator loads directly. Two additional voltage pulse outputs (for external SSRs) handle fast-cycle heater or cooling loads where relay life would be a concern. The universal input accepts RTD (Pt100, JPt100) and twelve thermocouple types (B, E, J, K, L, N, PLII, R, S, T, U, W) covering -200°C to 2300°C, plus 0-20 mA or 0-10 VDC linear process signals. That means one part number covers the sensor types you'd find on a plastics extruder, a packaging sealer, or a heat-treatment furnace — no variant swap needed. The heater fault detection feature monitors current draw on the load side and flags a broken heater or SSR short before the process drifts out of tolerance — a practical diagnostic for electric ovens and hot-runner systems where an undetected open element means scrap parts.

Control and communications

On/off or PID control method is selectable per loop. The RS-485 port speaks both Omron CompoWay/F and Modbus RTU.

MPN
E5CC-QQ3D5M-003