Skip to main content
Omron E5CC-QX3A5M-003

Omron E5CC-QX3A5M-003 Process Controller, PID, RS-485, IP66

MPN E5CC-QX3A5M-003
Active

Omron E5CC series process/temperature controller, 1/16 DIN, universal input, 3 relay + voltage (SSR) outputs, RS-485 Modbus, IP66 front panel, 100-240 VAC supply.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

E5CC-QX3A5M-003 specifications
ParameterValue
SeriesE5CC
Output signalRelay (3), Voltage (External SSR)
Supply voltage100 to 240VAC
IP ratingIP66
ProtocolRS-485 (CompoWay/F, Modbus)
MountingPanel Mount
Temp operating max55 °C
Temp operating min-10 °C
Weight0.265 lb (120.2 g)
PackageBox
Control methodOn/Off, Proportional (PID)

Product details

Universal input, mixed outputs for heater circuits

The Omron E5CC-QX3A5M-003 is a 1/16 DIN panel-mount process and temperature controller that accepts RTD, thermocouple (B, E, J, K, L, N, PLII, R, S, T, U, W), 0-20 mA, and 0-10 VDC inputs — covering the range from -200°C to 2300°C or standard process signals. The three relay outputs plus a voltage pulse output for an external SSR make this variant suited for heater circuits where you need both alarm/event relays and a solid-state drive signal for the power element. The IP66-rated front panel withstands washdown in food, beverage, or pharmaceutical lines — the seal is at the panel face, not the housing. The 45.00 mm x 45.00 mm square cutout matches the standard 1/16 DIN footprint, so it drops into existing panel holes without rework.

RS-485 Modbus and control loop options

RS-485 communications with both CompoWay/F and Modbus protocols are built in — no separate option card needed. This lets the controller report PV, setpoint, and status to a PLC or SCADA host over a standard serial bus. The control method supports On/Off or full PID, with the PID auto-tune feature typical of the E5CC series. Heater fault detection is included as a standard feature — the controller monitors current draw on the load side and flags a broken heater or SSR short before the process drifts out of tolerance. The dual-color LCD backlight shows the PV in 0.600" characters and the SV in 0.280", each row four digits.

Active production, sourced per BOM quantity

The box package is the standard retail unit.

MPN