Skip to main content
Siemens 3RH1122-2KF40

Siemens 3RH1122-2KF40 SIRIUS Coupling Relay, 110 V coil, 10

MPN 3RH1122-2KF40

Siemens SIRIUS coupling relay, 3RH1122-2KF40, size S00, 110 V coil, 2 NO + 2 NC contacts, screw and snap-on mounting, IP20 front.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

3RH1122-2KF40 specifications
ParameterValue
Mountingscrew and snap-on mounting
Depth73 mm
Width45 mm
Height60 mm

Product details

The Siemens 3RH1122-2KF40 is a SIRIUS coupling relay designed for switching auxiliary circuits in control panels. It's a size S00 contactor relay, meaning it shares the same compact footprint as the S00 contactor family — 45 mm wide, 60 mm tall, 73 mm deep — so it slots into the same DIN-rail layout without stealing extra panel real estate. That's a lot of freedom for tight enclosures where you're working around existing wiring.

The coil is rated 110 V — that's the pull-in and hold voltage. Closing power is 2.3 W DC, and holding power is the same 2.3 W DC, so the coil doesn't waste extra energy once it's sealed. A varistor is built in for surge suppression, which saves you from adding an external snubber on the coil. Contact ratings are given at multiple voltages, which tells you the switching capacity across common control voltages: 10 A at 24 V, 6 A at 230 V, 3 A at 400 V, 2 A at 500 V, and 1 A at 690 V. At 110 V — the coil voltage — the contact rating is 1 A. These are thermal current ratings for the auxiliary contacts; the actual making/breaking capacity depends on your load type (resistive vs. inductive), but these numbers give you the thermal limit. The relay carries 2 normally-open and 2 normally-closed instantaneous contacts — no delayed, lagging, or make-before-break options on this variant. Contact reliability is specified as one incorrect switching operation per 100 million cycles at 17 V, 1 mA, which covers dry-circuit (low-energy) switching where oxide films can cause trouble.

Shock resistance is 10g / 5 ms and 5g / 10 ms — fine for most industrial machinery but not extreme shock applications. Substance prohibitance date is July 1, 2006 — that's the RoHS compliance cutoff. The part is designed to meet RoHS requirements for substances like lead, mercury, and cadmium.

Terminals accept solid wire from 0.25 mm² up to 2.5 mm², two conductors per terminal. That covers standard control wiring (1.5 mm² is typical for 24 V DC circuits). The screw terminals are standard for the SIRIUS family — no special tooling needed.

MPN
3RH1122-2KF40