Skip to main content
Siemens 3RH2911-2HA10

Siemens 3RH2911-2HA10 SIRIUS Auxiliary Switch, 1 NO, Spring

MPN 3RH2911-2HA10
Active

Siemens SIRIUS auxiliary switch block, 1 NO contact, spring-loaded terminal, snap-on mounting for 3RT2 contactors and 3RH2 contactor relays, rated 10 A.

$3.40 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

3RH2911-2HA10 specifications
ParameterValue
MountingSnap-on Mounting
Depth47.7 mm
Width36 mm
Height41.5 mm

Product details

The Siemens 3RH2911-2HA10 is a front-mounted auxiliary switch block from the SIRIUS family, carrying a single normally-open (1 NO) contact. It snaps onto 3RT2 power contactors and 3RH2 contactor relays — the note "with 3RH2" confirms the intended mating frame. Spring-loaded terminals accept 2x (0.5 to 1.5 mm²) with ferrule or 2x (0.5 to 2.5 mm²) solid, or 2x (20 to 14 AWG).

The contact is rated 10 A maximum, but the real switching capacity depends on voltage and load type. At 24 V DC it handles 6 A; at 110 V DC it drops to 1 A; at 220 V DC it's 0.3 A. For AC-15 inductive control-circuit duty at 690 V, the rated current is 1 A — that's the figure to use when switching contactor coils or solenoid valves on a 690 V line. The AC-15 ratings at lower voltages are not listed here, but the DC inductive load table (at 24 V rated value: 10 A; 60 V: 4.7 A; 110 V: 3 A; 220 V: 1.2 A; 440 V: 0.5 A; 600 V: 0.26 A) gives a clear derating curve. If your load is a DC solenoid or brake coil, use the rated-value column, not the maximum.

Snap-on mounting — no tools, no screws. The block is 36 mm wide, 47.7 mm deep, 41.5 mm high. It mounts on the front of the contactor or relay, so it adds depth to the assembly but does not widen the DIN-rail footprint. Verify clearance in front of the contactor before laying out the panel.

Environmental and electrical endurance

Insulation voltage is 690 V at pollution degree 3, surge withstand 6 kV. Mechanical life is 10 million switching cycles typical. If you're switching PLC inputs or similar low-energy loads, this contact will stay clean.

Lifecycle stage is marked as current.

MPN
3RH2911-2HA10