Siemens SIRIUS EM 300 DS direct starter, order code 3RK1300-0FS01-0AA3, setting range 0.35-0.5 A, AC-3 0.12 kW at 400 V, IP65, PROFIBUS DP, with integrated brake contact.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

3RK1300-0FS01-0AA3 specifications
ParameterValue
IP ratingIP65
Temp operating max55 °C
Temp operating min0 °C
Depth134 mm
Width140 mm
Height270 mm

Product details

The Siemens 3RK1300-0FS01-0AA3 is an EM 300 DS electromechanical direct starter from the SIRIUS family, designed for the ET 200X distributed I/O system. It combines a contactor, bimetal motor protection, and a motor brake output in one IP65-rated enclosure — a self-contained motor start/stop and protection unit for a single motor load. The setting range is 0.35 to 0.5 A, and at AC-3 duty (squirrel-cage motor starting) on a 400 V supply it is rated for 0.12 kW. That 0.12 kW figure is the motor power it can switch under the standard AC-3 utilization category — the rating that governs real motor starting, not a resistive load. It communicates over PROFIBUS DP, so it integrates directly into a PROFIBUS network without a separate gateway. The main current circuit connects via tab terminals — quick-connect blades, not screw clamps — which is typical for the ET 200X form factor.

This direct starter is built for the ET 200X distributed I/O system — it mounts onto the ET 200X backplane or motor feeder module, not on a DIN rail. Dimensions are 134 mm deep, 140 mm wide, and 270 mm high. The 9-pole motor feeder and 9-pole power connection are part of the ET 200X interface — the starter plugs into the system bus and power rail.

Protection and breaking capacity

Motor protection is via a bimetal overload relay integrated into the starter — it tracks motor current and trips on sustained overload. Short-circuit protection is designed for circuit-breakers upstream, and the maximum short-circuit breaking capacity (Icu) at 400 V is 50 A. The integrated motor brake output (product component Motor brake output = Yes) means this starter can control an externally supplied brake — typically a DC brake coil on a motor — without a separate brake contactor. The brake contact is rated for the same 400-500 V supply as the main circuit.

MPN