Skip to main content
Siemens 3RK1300-1KS01-0AA3

Siemens 3RK1300-1KS01-0AA3 EM 300 DS direct starter, 9-12A,

MPN 3RK1300-1KS01-0AA3

Siemens SIRIUS EM 300 DS direct starter, 3RK1300-1KS01-0AA3, electromechanical, setting range 9-12A, AC-3 5.5kW/400V, IP65, with brake contact and PROFIBUS DP.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

3RK1300-1KS01-0AA3 specifications
ParameterValue
IP ratingIP65
Temp operating max55 °C
Temp operating min0 °C
Depth134 mm
Width140 mm
Height270 mm

Product details

The Siemens 3RK1300-1KS01-0AA3 is an EM 300 DS electromechanical direct starter designed for the ET 200X distributed I/O system. It's a motor-protecting combination unit that integrates a contactor, bimetal overload relay, and short-circuit protection into a single IP65 enclosure. Rated for AC-3 duty at 400 V, it handles motor loads up to 5.5 kW with a setting range of 9 to 12 A. The full-scale value is 12 A, meaning the bimetal overload is adjustable across that band to match the motor's full-load current. It includes a motor brake output for internally supplied brakes, a 9-pole motor feeder, and a 9-pole power connection — all terminated via tab terminals. The operating voltage range is 400 to 500 V AC.

This is a field-mounted unit for the ET 200X family — it bolts directly to the motor feeder module, not to a DIN rail inside a control cabinet. PROFIBUS DP communication is built in, so the starter reports status and accepts start/stop commands over the fieldbus without a separate I/O slice. The 9-pole power connection carries the motor leads; the brake contact is a separate output for holding brakes common on vertical-axis drives. Ambient temperature range is 0 to 55 °C during operation.

Protection and coordination

Short-circuit protection is provided by circuit-breakers integrated into the design, with a maximum short-circuit breaking capacity (Icu) of 50 A at 400 V. The motor protection is bimetal-based, so it tracks thermal load via a heating element. It's not electronic, meaning no ambient-temperature compensation or adjustable trip class — set the dial to the motor's FLA and let the bimetal do its job. Equipment marking per DIN EN 61346-2 is Q, the standard identifier for power switching equipment in industrial schematics.

MPN
3RK1300-1KS01-0AA3