Skip to main content
Siemens 3RK1308-0AE00-0CP0

Siemens 3RK1308-0AE00-0CP0 SIMATIC DOL Starter, 12 A at 40 °

MPN 3RK1308-0AE00-0CP0
Active

Siemens SIMATIC 3RK1308-0AE00-0CP0 direct-on-line motor starter, 12 A at 40 °C, adjustable trip class, PROFINET/PROFIBUS DP.

$228.60 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

3RK1308-0AE00-0CP0 specifications
ParameterValue
Mountingpluggable in BaseUnit
Depth150 mm
Width30 mm
Height142 mm
Trip classCLASS OFF / 5 / 10 adjustable

Product details

The Siemens SIMATIC 3RK1308-0AE00-0CP0 is a direct-on-line motor starter designed for switching and protecting three-phase motors up to 12 A at 40 °C ambient. It integrates a contactor and overload relay in one 30 mm wide housing that plugs onto a base unit for DIN-rail mounting, saving panel space compared to discrete components. Rated for continuous operation with an MTBF of 46 a, this starter is suited for conveyor, pump, and fan applications where the motor starts directly across the line. The adjustable trip class — selectable OFF, 5, or 10 — lets you match the thermal protection to the motor's starting characteristic: class 10 covers standard squirrel-cage motors, class 5 tightens protection for high-efficiency types with faster start times.

Communication and control

Both PROFINET and PROFIBUS DP protocols are built in, eliminating the need for a separate gateway or communication module. The starter accepts 4 bytes of input data and returns 2 bytes of output data, mapping status and control words into the PLC's I/O image. On-delay of 20 ms and off-delay of 35 to 50 ms are fixed, so sequence timing must account for these windows. Supply voltage range is 20.4 to 28.8 V DC, typical for a 24 V control loop. The safe state is load circuit open — on loss of communication or a fault, the output drops out, leaving the motor unpowered. This aligns with fail-safe behavior expected in a standard (non-SIL) motor starter.

The 30 × 142 × 150 mm footprint (width × height × depth) fits standard 30 mm slot spacing. Clearance of 50 mm above and below is required for airflow and wiring access. Operating temperature range is -25 to +60 °C with derating above 40 °C, storage and transport range -40 to +70 °C. Vibration resistance is 15 mm at 6 Hz / 2g up to 500 Hz; shock resistance 6g for 11 ms — adequate for most machine-mounted enclosures.

MPN