Skip to main content
Siemens 3RV1331-4HC10

Siemens 3RV1331-4HC10 SIRIUS Circuit Breaker, 50 A, 22 kW at

MPN 3RV1331-4HC10

Siemens SIRIUS 3RV1331-4HC10 circuit breaker for starter combinations, 50 A continuous, 22 kW at 400 V AC-3, 50 kA SCCR, 3-pole, screw terminals, IP20, DIN rail mount.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

3RV1331-4HC10 specifications
ParameterValue
Depth149 mm
Width55 mm
Height140 mm

Product details

SIRIUS 3RV1331-4HC10 — Motor Circuit Breaker for Starter Combinations

Rated 50 A continuous and 22 kW at 400 V AC-3, it handles the full-load current of a 22 kW four-pole induction motor on a 400 V line. That SCCR curve matters when you're coordinating with upstream protective devices in a panel — you can size the feeder breaker knowing this device will interrupt faults up to those levels without cascading.

Ratings That Drive the Selection

The 50 A continuous current rating is the thermal through-current — this is what governs the conductor sizing and the upstream protection coordination. The 22 kW at 400 V is the motor output it can protect in AC-3 duty (starting and stopping a squirrel-cage motor under load). The switching frequency is 15 operations per hour at AC-3 — fine for a pump or fan start, not for a high-cycle indexing table. Power dissipation runs 29 W total in hot operating state, or 9.7 W per pole; that heat has to be considered in a sealed enclosure derating calculation. Wire range: solid conductors accept 2x 0.75…16 mm²; stranded accepts 2x 0.75…25 mm² or single up to 35 mm². That covers most motor feeder cables up to 50 A. The screw-type box terminals are standard for the main circuit; auxiliary contacts use separate screw terminals. The unit supports an auxiliary switch extension — you can add a signal contact for remote status indication without replacing the breaker.

Integration and Environmental Limits

Mounting position is any orientation — no derating needed for horizontal or vertical rail placement. Shock resistance is 25 g for 11 ms — survives typical panel shipping and machine vibration. Surge voltage withstand is 6 kV, which covers overvoltage category III in a 400 V distribution system. Finger-safe touch protection means no exposed live parts when the front cover is on — meets the basic safety requirement for IP20 enclosures.

MPN
3RV1331-4HC10