Skip to main content
Siemens 3RV2411-0AA15

Siemens 3RV2411-0AA15 SIRIUS Circuit Breaker, Transformer Pr

MPN 3RV2411-0AA15
Active

Siemens SIRIUS circuit breaker, 3RV2411-0AA15, for transformer protection, CLASS 10 trip, 100 kA breaking capacity at 400 V AC, screw and snap-on mounting on 35 mm DIN rail.

$41.91 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

3RV2411-0AA15 specifications
ParameterValue
Depth97 mm
Width45 mm
Height97 mm
Trip classCLASS 10

Product details

The Siemens SIRIUS 3RV2411-0AA15 is a circuit breaker designed specifically for transformer protection, not general motor or feeder duty. That means its trip curve and thermal memory are tuned to handle the inrush and magnetizing current of a transformer without nuisance tripping, while still clearing a winding fault fast. Rated breaking capacity hits 100 kA at 400 V AC — that's the fault current it can safely interrupt without welding contacts or venting arc plasma into the panel. It carries a CLASS 10 trip characteristic, so it will open within 10 seconds at 600% of the thermal setting, which is standard for protecting transformers against sustained overloads.

Mounting and integration

Mounts via screw or snap-on onto 35 mm DIN rail per DIN EN 60715. The 45 mm width (three module spaces) and 97 mm depth fit a standard distribution board or control panel without overhang. Any mounting position is allowed, so you can orient it vertically or horizontally in a tight gland plate layout. Terminals accept 2x (0.5 to 1.5 mm²) solid or stranded, or 2x (0.75 to 2.5 mm²) — sized for the control transformer primary side wiring typical in MCC buckets.

Key ratings and what they mean

Phase failure detection is built in — if one phase drops out on the primary side, the breaker trips, preventing single-phasing damage to the transformer. The rated insulation voltage spans 20 to 690 V, covering most low-voltage distribution systems up to 690 V line-to-line. Ambient operating range is -20 to +60 °C, with storage from -50 to +80 °C, so it handles unheated warehouses and panel heat rise without derating.

MPN
3RV2411-0AA15