Skip to main content
Siemens 3RW4424-1BC36

Siemens 3RW4424-1BC36 SIRIUS Soft Starter, 81 A, 690 V

MPN 3RW4424-1BC36

Siemens SIRIUS 3RW4424-1BC36 soft starter, thyristor-based, 81 A at 40 °C, 690 V insulation voltage, 50/60 Hz, integrated bypass contactor, screw fixing.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

3RW4424-1BC36 specifications
ParameterValue
Mountingscrew fixing
Depth270 mm
Width170 mm
Height192 mm

Product details

Thyristor-based soft starter, 81 A at 40 °C — the thermal budget decides the real current

The 3RW4424-1BC36 is a SIRIUS soft starter using thyristors for voltage ramp starting — the core switching element handles the inrush without mechanical wear on the main contacts. An integrated bypass contactor closes after the start ramp, taking the thyristors out of the circuit during run mode — this cuts heat dissipation and lets the soft starter handle continuous loads without oversized heatsinks. Motor overload protection is built in, and the unit also provides intrinsic device protection against overtemperature — no separate overload relay or thermistor relay is needed for the starter itself.

Panel fit and wiring — screw fixing, box terminals, 270 mm depth

Mounting is by screw fixing (not DIN rail snap-on), with the unit sized 170 mm wide, 192 mm high, and 270 mm deep — the depth is the dimension to check when the enclosure back-panel clearance is tight. The mounting position allows vertical surface mounting with ±90° rotation and ±22.5° tilt forward/backward, so the panel layout can tilt the unit without derating. Main circuit connections use box terminals accepting 2x (4... 50 mm²) stranded or 2x (10... 1/0 AWG) using both clamping points. Clearance around the unit: 100 mm above, 75 mm below, 5 mm at the sides. Maximum motor cable length is 500 m — sufficient for most industrial motor runs, but long cable installations should check for reflected wave effects on the thyristor stack.

Inside-delta wiring and adjustable current limit — application flexibility

The soft starter supports inside-delta circuit wiring, which connects the thyristors in the delta legs of a six-wire motor. This reduces the current through each thyristor to 58 % of the line current, allowing the 81 A unit to start motors with a higher nominal current in delta configuration. Adjustable current limitation lets the user set the maximum start current as a multiple of the motor FLA — useful for applications where the supply transformer or generator has limited short-term capacity. Minimum load is 8 %, so the starter can handle lightly loaded motors without instability. Pollution degree 3 per IEC 60947-4-2 means it is rated for industrial environments with conductive dust or occasional condensation.

Fault display and external reset — local and remote diagnostics

A display on the unit shows fault codes locally — no HMI or software needed for first-level diagnostics. An external reset input allows remote clearing of faults from a PLC or pushbutton panel, which is standard for automated restart sequences.

MPN
3RW4424-1BC36