Siemens 3RW5056-2TB05 Soft Starter, 81 A Min, 200–600 V

MPN 3RW5056-2TB05
Active

Siemens 3RW5056-2TB05 soft starter, 81 A minimum operating current, 200–600 V supply voltage, trip class 10A/10E/20E per IEC 60947-4-2, ATEX/UKEX/IECEx certified, 120 x 198 x 249 mm screw-fixed mounting.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

3RW5056-2TB05 specifications
ParameterValue
Mountingscrew fixing
Depth249 mm
Width120 mm
Height198 mm
Trip classCLASS 10 A / 10E (preset) / 20E; acc. to IEC 60947-4-2
Service factor1

Product details

Active production, multi-protocol fieldbus

The 3RW5056-2TB05: Fieldbus integration covers PROFIBUS, Modbus RTU, Modbus TCP, EtherNet/IP, and PROFINET standard, with PROFIenergy support when paired with the PROFINET communication module. This allows the starter to participate in energy management and coordinated start sequences on a single network.

Explosion-protected area deployment

The unit holds ATEX, UKEX, and IECEx certification, qualifying it for installation in potentially explosive atmospheres where standard soft starters would be prohibited. This is a key differentiator for sites governed by the ATEX Directive 2014/34/EU or IECEx Scheme. North American market acceptance is confirmed by UL and CSA approvals.

Mounting and physical integration

Dimensions are 120 mm width, 198 mm height, 249 mm depth. Fastening method is screw fixing — no DIN-rail clip. Mounting position allows a vertical surface with +/-90° rotation and +/-22.5° tilt forward/backward, giving flexibility in panel layout but requiring dedicated screw holes. Clearance requirements: 100 mm upwards, 75 mm downwards, 10 mm forwards, 5 mm sideways, 0 mm backwards. These minimums must be maintained for airflow and service access — a panel designed for a different starter may need re-spacing.

Application-specific starting profiles

Soft torque, voltage ramp, and pump ramp down are built-in functions. Pump ramp down reduces the deceleration rate to prevent water hammer in pumping systems — a common failure mode in water/wastewater installations. Remote reset is available by cycling the control supply voltage. Minimum load is 15 % of the smallest settable Ie, ensuring the starter can handle lightly loaded motors without nuisance tripping. Auto-reset is supported for unattended restart after a fault clears.

Sourcing and compliance documentation

Compliance documentation includes CE marking, UL, CSA, ATEX, UKEX, and IECEx certificates. The unit is classified under product category 'Hybrid switching devices' and carries a service factor of 1.