Skip to main content
Siemens 3RW5235-6TC15

Siemens 3RW5235-6TC15 SIRIUS Soft Starter, 68 A, 200-600 V

MPN 3RW5235-6TC15
Active

Siemens SIRIUS 3RW5235-6TC15 soft starter, 68 A minimum, 200-600 V, CLASS 10A/10E/20E, PROFIBUS, Modbus RTU/TCP, EtherNet/IP, PROFINET, screw fixing, 185 x 306 x 203 mm.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

3RW5235-6TC15 specifications
ParameterValue
Mountingscrew fixing
Depth203 mm
Width185 mm
Height306 mm
Trip classCLASS 10 A (default) / 10E / 20E; acc. to IEC 60947-4-2
Service factor1

Product details

Motor starting duty and trip class selection

The 3RW5235-6TC15 is a SIRIUS hybrid switching device — a soft starter that ramps motor voltage during start to limit inrush current and mechanical shock. Its trip class is configurable: CLASS 10A (default), 10E, or 20E per IEC 60947-4-2, which sets the maximum allowable start time before the overload protection trips. For a pump or conveyor with a high-inertia load, selecting 20E gives a longer acceleration window; for a compressor that starts unloaded, CLASS 10A keeps the protection tight. Rated supply voltage spans 200 to 600 V, covering 208 V, 400 V, and 480 V systems common in North American and European panels. The minimum settable motor current is 68 A, so the soft starter fits motors in the 30–50 kW range at 400 V, depending on the service factor and ambient derating.

Fieldbus connectivity and panel integration

This soft starter ships with onboard PROFIBUS, Modbus RTU, Modbus TCP, EtherNet/IP, and PROFINET standard communication — no separate gateway module needed for most automation architectures. PROFIenergy is supported when used with the PROFINET standard communication module, allowing energy-saving shutdown of the motor during idle periods. Mounting is screw-fixing to a vertical surface, with the unit rotatable ±90° and tiltable ±22.5° front-to-back. Clearance requirements: 100 mm above, 75 mm below, 10 mm forward, 5 mm at the sides, and 0 mm backward — so it can sit flush against the back panel. Dimensions are 185 mm wide, 306 mm high, and 203 mm deep, which fits a standard 600 mm deep enclosure with room for cable glands.

Application features and ambient derating

Soft Torque and Pump Ramp Down are built in — these reduce pressure surges in pumping systems during start and stop, which extends the life of valves and piping. The unit also supports auto-reset and remote reset by cycling the control supply voltage, useful for unattended installations. The shock resistance is 15 g / 11 ms, dropping to 12 g / 11 ms if potential contact lifting is a concern — relevant for installations on vibrating machinery.

MPN
3RW5235-6TC15