Skip to main content
Siemens 4EP3500-0US00

Siemens 4EP3500-0US00 Mains Choke, 3-Phase 480V 16A, 0.88 mH

MPN 4EP3500-0US00
Active

Siemens 4EP3500-0US00 mains choke for frequency converters, 3-phase AC, rated voltage 400/480 V, max current 16 A, inductance 0.88 mH, IP00, screw terminals.

$185.42 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

4EP3500-0US00 specifications
ParameterValue
IP ratingIP00
Depth0.068 m
Width0.148 m
Height0.139 m

Product details

It reduces harmonic distortion, limits inrush current, and protects the drive from line-side transients. Rated for 400/480 V AC at 50/60 Hz, it carries a maximum continuous current of 16 A and a rated operational current of 14.4 A.

The 16 A maximum AC current (Ithmax) sets the thermal limit for continuous duty at 40 °C ambient. The 14.4 A rated operational current (I LN) is the figure to match against your drive's input current at full load — not the motor FLA. If your drive draws 14 A or less at rated output, this choke is sized correctly. The 2 % voltage drop (Uk) is a standard value for line reactors; it provides effective harmonic mitigation without excessive voltage sag that could starve the drive DC bus. The 31 W coil loss plus 10 W iron loss (41 W total) must be considered in enclosure thermal calculations, especially in a sealed cabinet.

This is an open-frame (IP00) component — no enclosure, no finger-safe terminals. Dimensions are 0.148 m wide, 0.139 m high, and 0.068 m deep. Connections are via screw-type terminals, which accept standard power wiring. The thermal class B insulation (130 °C rise) means it can run at full rated current in a 40 °C ambient without exceeding the winding temperature limit. In a typical panel, allow at least 50 mm clearance around the choke for airflow; forced ventilation may be needed if other heat sources are nearby.

Compliance documentation

The product is designed to EN 61558-2-20 (safety of transformers, reactors, and power supply units) and is UL/CSA recognized as noted in the description. RoHS and REACH compliance is standard for Siemens industrial components in this series, though the specific declarations should be requested with the order if required for your quality documentation.

MPN