Skip to main content
Siemens 4EP4011-0CP00

SIDAC 4EP4011-0CP00 Filter Reactor, 18.1A, 400V, 3-Phase

MPN 4EP4011-0CP00

SIDAC, filter reactor, 4EP4011-0CP00, 3-phase, 400V AC, 18.1A rated, 12.5 kvar, 7% detuning, IP00, free cable endings.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

4EP4011-0CP00 specifications
ParameterValue
IP ratingIP00
Depth0.143 m
Width0.219 m
Height0.179 m

Product details

What this line reactor does in the panel

The SIDAC 4EP4011-0CP00 is a 3-phase filter reactor rated for 400 V AC at 50 Hz, carrying a continuous 18.1 A (20.1 A maximum). It delivers 12.5 kvar of reactive power with a 7% relative throttling factor, meaning it detunes the filter bank away from the 5th harmonic — the standard tuning for preventing resonance with the 250 Hz harmonic common on 50 Hz industrial networks. The resonant frequency lands at 189 Hz, which is the textbook target for a 7% reactor on a 50 Hz supply. The 0.0031 H inductance and thermal class B insulation (130 °C continuous) suit it for power-factor correction banks or harmonic filter cabinets where the reactor sits in series with the capacitor. IP00 means it is an open-frame component — it needs enclosure in a panel or cabinet; there is no finger-safe housing. Connections are free cable endings, so expect to terminate with ring lugs or ferrules inside the cabinet. Rated for a 40 °C ambient, this reactor can be installed in a ventilated low-voltage switchboard alongside other heat-generating components, provided the enclosure is sized for the thermal load. The depth of 0.143 m, width of 0.219 m, and height of 0.179 m define the mounting footprint — verify clearances for the free cable ends and air circulation around the core.

What the 7% detuning means for coordination

A 7% detuning factor is the most common choice for power-factor correction in industrial plants with 6-pulse drives and other non-linear loads. It shifts the filter's resonant frequency below the 5th harmonic (250 Hz on 50 Hz systems), so the capacitor bank does not amplify harmonic currents. The 189 Hz resonant frequency of this reactor confirms that tuning. If the plant has significant 3rd harmonic content from single-phase loads, a 14% reactor (resonant at 134 Hz) would be the alternative — but 7% covers the majority of motor-drive environments. The rated reactive power of 12.5 kvar means this reactor is sized for a capacitor bank of that output. Pair it with a capacitor of the same kvar rating at 400 V. The 18.1 A rated current (20.1 A max) sets the upstream protection: a circuit breaker or fuse should be coordinated to the reactor's thermal class B limit and the capacitor's inrush.

MPN
4EP4011-0CP00