Siemens 5SU1353-7KK06

Siemens 5SU1353-7KK06 SENTRON RCBO, 6 A C-curve, 1P+N, 4.5 k

MPN 5SU1353-7KK06
Active

Siemens SENTRON 5SU1353-7KK06 RCBO, 1P+N, C-curve, 6 A rated, 4.5 kA (EN 60898) / 25 kA (IEC 60947-2), 2 MW, IP20.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

5SU1353-7KK06 specifications
ParameterValue
Poles2
Depth77 mm
Width36 mm
Height90 mm
Energy limitation class3

Product details

RCBO for final-circuit protection — 6 A C-curve, 1P+N

The Siemens 5SU1353-7KK06 is a SENTRON RCBO (residual current operated circuit breaker with integral overcurrent protection) in a 1P+N configuration. It combines a C-curve miniature circuit breaker for the phase conductor with a residual current detection module that also disconnects the neutral. Rated 6 A at 30 °C and 230/240 V AC, 50 Hz, it is sized for lighting, small appliance, or general-purpose socket circuits in residential and light commercial distribution boards. Breaking capacity is 4.5 kA per EN 60898 for domestic installations and 25 kA per IEC 60947-2 for industrial panels where higher prospective fault current is expected — the higher figure gives the panel designer headroom for coordination with an upstream MCCB or fuse. The residual current element is instantaneous type (no intentional delay), so it trips within 40 ms on a ground fault. Minimum test voltage is 195 V, meaning the test button functions reliably even on a lightly loaded phase. Supply can enter from either top or bottom, which simplifies busbar routing in a crowded enclosure.

Temperature derating and panel fit

Rated current is 6 A at 30 °C ambient, but the 5SU1353-7KK06 derates linearly as enclosure temperature rises: 5.7 A at 40 °C, 5.4 A at 50 °C, 5.1 A at 60 °C, and 4.62 A at 70 °C. In a sealed distribution board with multiple RCBOs ganged, the effective current per device drops — size the circuit load against the derated figure at the expected internal temperature, not the 30 °C nameplate. IP20 rating applies once the distribution board is closed and conductors are connected — the front face is finger-safe, but the terminals are not touch-proof with the cover open.