Skip to main content
Siemens 5SY4250-6CC

Siemens SENTRON 5SY4250-6CC MCB, 2-Pole B-Curve 50 A, 10 kA

MPN 5SY4250-6CC

Siemens SENTRON 5SY4250-6CC, 2-pole miniature circuit breaker, B-curve, 50 A rated current, 10 kA breaking capacity per EN 60898, 400 V AC, IP20.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

5SY4250-6CC specifications
ParameterValue
Poles2
IP ratingIP20
MountingQuick assembly system
Temp operating max55 °C
Temp operating min-25 °C
Depth76 mm
Width36 mm
Height90 mm

Product details

What this 50 A B-curve MCB brings to a panel

For UL 1077 and CSA C22.2 No. 235 applications it carries a 5 kA rating, so verify which standard governs your panel's SCCR study. The 50 A rating on a 2-pole B-curve fits mechanical engineering and industrial panels — think machine tool feeders, control transformer primaries, or branch circuits feeding multiple contactor coils and relays where the load current is well under 50 A but you want a single breaker protecting both poles. The 400 V AC rating covers line-to-line loads in three-phase systems; the maximum DC rating of 72 V means it's not your go-to for DC bus protection unless the voltage is under that threshold.

Mounting and wiring — what fits in the DIN footprint

The 76 mm depth and 90 mm height are standard for the SENTRON 5SY series, so it drops into existing panels without re-drilling gland plates. Terminals accept solid or stranded copper from 0.75 mm² up to 35 mm², which covers everything from 14 AWG control wiring up to 2 AWG feeder conductors. The screw terminals require 2.5 to 3.5 N·m of tightening torque — enough to hold a 35 mm² conductor without crushing it. Both top and bottom terminals are combined, meaning you can land the incoming supply on either end. The breaker is sealable for tamper-proof installations, and touch protection is built in.

The closest functional peer in the same family is the 5SY7140-8CC, which is a 1-pole C-curve 40 A breaker. That's a different pole count and tripping characteristic — it won't drop into a 2-pole B-curve 50 A slot without rewiring and re-evaluating coordination. If you need a direct 2-pole B-curve 50 A replacement, the 5SY4250-6CC is the correct order code; the 5SY7140-8CC is not a form-fit-function substitute.

Relative humidity tolerance is specified up to 95% at 55 °C, derating to 55% at 70 °C and 35% at 75 °C. Energy limiting class 3 indicates good let-through energy restriction for downstream equipment protection.

MPN
5SY4250-6CC