Skip to main content
Siemens 5SY8240-8

Siemens 5SY8240-8 SENTRON MCB, 2-pole D-curve, 25 kA IEC

MPN 5SY8240-8
Active

Siemens SENTRON 5SY8240-8, 2-pole miniature circuit breaker, D tripping characteristic, 25 kA at 400 V AC per IEC 60947-2, IP20, 2 MW wide.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

5SY8240-8 specifications
ParameterValue
Poles2
IP ratingIP20
MountingQuick assembly system
Temp operating max75 °C
Temp operating min55 °C
Depth76 mm
Width36 mm
Height90 mm

Product details

What the ratings mean for fit

The Siemens 5SY8240-8 is a 2-pole SENTRON miniature circuit breaker with a D tripping characteristic, rated to interrupt 25 kA at 400 V AC per IEC 60947-2. The D curve means it tolerates the high inrush currents typical of motor loads, transformers, and welding equipment — the magnetic trip threshold is 10 to 20 times rated current, so it won't nuisance-trip on startup. The 25 kA breaking capacity at 400 V AC gives you headroom for high-fault installations; at 60 V DC it still clears 15 kA, and under UL 1077 it's listed at 5 kA for North American supplementary protection applications. That triple-standard coverage (IEC 60947-2, EN 60947-2, UL 1077) means the same part works in European panel builds and US control panels without a substitution.

Deployment context and panel integration

Snaps onto DIN rail via the quick-assembly system — 2 modular width units (36 mm wide) leave room for adjacent devices in a crowded enclosure. The 76 mm depth and 70 mm installation depth fit standard distribution boards; mount in any position. IP20 with connected conductors means it's protected against finger contact once wired, suitable for enclosed industrial panels. The combined top and bottom terminals accept supply from either direction, which simplifies busbar routing in a multi-breaker row.

Environmental and mechanical robustness

Rated for ambient temperatures from -40 °C to 75 °C, with humidity tolerance up to 95% at 55 °C — suitable for unheated enclosures in cold storage or outdoor cabinets. Vibration resistance per IEC 60068-2-6 covers ±1 mm at 5 to 25 Hz and 50 m/s² at 25 to 150 Hz, so it holds up on machinery with moderate vibration. Halogen-free and silicon-free construction matters for clean-room or semiconductor-adjacent installations where outgassing contaminates processes. Mechanical service life is 10,000 operating cycles typical.

MPN
5SY8240-8