Skip to main content
Siemens 6ES7331-7TB00-0AB0

Siemens 6ES7331-7TB00-0AB0 Analog Input Module, 2 AI, HART

MPN 6ES7331-7TB00-0AB0
End of Life

Siemens SIMATIC S7-300 SM 331 analog input module, 2 AI, HART, Ex(i), 24 V DC, 2-wire, 4 to 20 mA, FM/ATEX, 6ES7331-7TB00-0AB0.

$192.02 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

6ES7331-7TB00-0AB0 specifications
ParameterValue
Depth120 mm
Width40 mm
Height125 mm
Measurement principleintegrating (Sigma-Delta)

Product details

What this module does in a hazardous-area loop

The Siemens 6ES7331-7TB00-0AB0 is a 2-channel analog input module designed for intrinsically safe (Ex(i)) 2-wire transmitters in hazardous locations. It accepts 0 to 20 mA or 4 to 20 mA signals, with HART communication active on both channels — indicated by a green LED per channel. The module carries FM approval for Class I, Division 2, Groups A–D T4 and ATEX marking II3 (2) G Eex nA [ib] IIC T4, so it slots into Zone 2 installations with Ex(i) loop-powered field devices without an external barrier.

End-of-life — sourcing reality

No pin-compatible drop-in replacement from Siemens has been published for this exact Ex(i) variant.

Integration into an S7-300 rack

The module occupies one slot in an S7-300 rack — 40 mm wide, 125 mm high, 120 mm deep — and draws 100 mA from the 5 V DC backplane bus plus 4.5 W from the 24 V DC load voltage L+. It is compatible with ET200M distributed I/O via an IM 153-2 interface module, which is the typical deployment for hazardous-area remote I/O. Channel-to-channel isolation is 1 500 V AC, and isolation between channels and the backplane bus is 500 V DC. The 50 Ω input resistance on the 4 to 20 mA range means the loop burden is low enough for most 2-wire transmitters to drive without exceeding compliance voltage.

Sigma-delta conversion with configurable integration

The module uses a sigma-delta measurement principle with parameterizable integration times: 2.5 ms, 16.67 ms, 20 ms, or 100 ms. The 16.67 ms and 20 ms settings reject 60 Hz and 50 Hz line noise respectively — a practical choice when the module shares a panel with VFDs or switching power supplies. Diagnostics are fully parameterizable: a red SF group-error LED, a red F channel-fault LED per channel, and configurable limit-value alarms on channels 0 and 1. Overrange is indicated by a red LED and a signal flag.

MPN
6ES7331-7TB00-0AB0