Siemens 7SJ6111-5EB02-1FA0/FF,,F

Siemens 7SJ6111-5EB02-1FA0/FF,,F 7SJ61 Protection Relay

MPN 7SJ6111-5EB02-1FA0/FF,,F

Siemens 7SJ61 series multifunction protection relay, order code 7SJ6111-5EB02-1FA0/FF,F, panel flush mount, screw-type terminals, 110-250 VDC / 115-230 VAC auxiliary supply, 8 binary inputs, 8 binary outputs, 1 live status contact.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

7SJ6111-5EB02-1FA0/FF,,F specifications
ParameterValue
Product type7SJ61 Multifunction Protection Relay

Product details

Panel flush mount, 8 BI / 8 BO, 110-250 VDC supply

The 7SJ6111-5EB02-1FA0/FF,,F: The 7SJ6111-5EB02-1FA0/FF,F is a Siemens 7SJ61 multifunction protection relay in a 1/3 19-inch housing with 8 binary inputs, 8 binary outputs, and one live status contact. The unit version E specifies panel flush mounting with screw-type terminals accepting direct connection or ring-type cable lugs — a standard fit for retrofit into existing switchgear cutouts where the relay face must sit flush with the panel door. Rated auxiliary voltage spans 110 to 250 V DC and 115 to 230 V AC, with the binary input threshold set at 88 V DC. This means the relay holds the unit on the grid across the common station battery voltages (110/125/220 VDC) without an external converter, provided the DC supply stays above the 88 V threshold for reliable input sensing. Measuring inputs are configured for Iph = 1 A, Ie = 1 A with a minimum detectable current of 0.05 A — sized for direct connection to CT secondaries in medium-voltage feeder protection schemes where 1 A CTs are standard.

Service interface and regional defaults

The service interface (Port C) is an electrical RS485 port running DIGSI 4 protocol, with modem and RTD-box support. This is the commissioning engineer's download port — the RS485 physical layer matches the legacy DIGSI 4 cable, so no USB converter is needed for initial parameterisation on site. The default language is English (GB), with other languages selectable via DIGSI. This covers the common frequency and protection-curve requirements for export panels or multi-standard installations. Fault recording is included as standard (position 15), meaning the relay captures oscillographic event data for post-fault analysis — essential for coordinating protection operations and verifying that the trip sequence held the unit on the grid as intended.

Current production, quoted to order

For volume BOM commitments, availability and pricing are confirmed at RFQ against the specific quantity and delivery window.

MPN
7SJ6111-5EB02-1FA0/FF,,F