Skip to main content
Mitsubishi Electric FX3U-1PG

Mitsubishi FX3U-1PG Pulse Output Block, 200 kHz, NPN

MPN FX3U-1PG

Mitsubishi Electric FX3U-1PG pulse output block, FX3U series, 1 Hz to 200 kHz, NPN open collector, incremental/absolute positioning, 0.2 kg.

$74.40 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

FX3U-1PG specifications
ParameterValue
Signal typeNPN open collector transistor
Product typePulse output block FX 3 U - 1 PG
Response timeDOG input: 1 ms STOP input: 4 ms
Weight0.2 Kg
Output formatA transistor
Output methodPulse (output pulse width: 20 ms)

Product details

Pulse output ceiling and what it buys you

The FX3U-1PG delivers a 1 Hz to 200 kHz output frequency range, which covers the vast majority of stepper and servo pulse-train inputs used in FX3U-based positioning applications. At 200 kHz, a typical 1,000-pulse/rev stepper drive runs at 12,000 rpm — well past the motor's torque curve, so the practical ceiling is the drive, not the module. Output format is NPN open collector transistor, so it sinks current to ground on each pulse. The load side — typically a stepper drive or servo amplifier — must provide the pull-up voltage (DC 5 to 24 V) and limit the ON current to 4.0 mA or more per the spec.

Positioning units and range — fit for the axis type

The module works in PLS (pulses), µm, 10⁻⁴ inch, or mdeg, with a range of -2,147,483,648 to 2,147,483,647 PLS. That 32-bit signed range gives ±2.1 billion counts — enough for a multi-revolution absolute axis with sub-micron resolution. Positioning method supports both incremental and absolute, selected per program. The unit magnification (1, 10, 100, 1000×) lets you scale the command unit to match the mechanical system without rewriting the ladder logic.

Signal set for home return and interrupt positioning

The FX3U-1PG carries dedicated DOG (proximity dog) and STOP inputs for machine home return and deceleration-stop operations. DOG input response time is 1 ms; STOP input is 4 ms — fast enough for most mechanical systems where the start-up time is 1 ms (motor) to 2 ms (mechanical). A CLR signal output clears the deviation counter on the servo drive at the home position, and a PG0 zero-point signal input synchronises with the encoder Z-phase for repeatable homing.

Sourced to order against the BOM quantity through independent distribution.

MPN
FX3U-1PG