Skip to main content
Siemens 5SJ4210-7HG41

Siemens 5SJ4210-7HG41 2-Pole MCB, C-Curve, 10 kA EN 60898

MPN 5SJ4210-7HG41
Active

Siemens SENTRON 5SJ4210-7HG41, 2-pole miniature circuit breaker, C tripping characteristic, 10 kA (EN 60898) / 15 kA (IEC 60947-2), 400 V AC / 60 V DC, 2 MW, DIN rail mount.

$76.20 – $221.84 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

5SJ4210-7HG41 specifications
ParameterValue
Poles2
Mountingon standard mounting rail
Depth70 mm
Width36 mm
Height110 mm

Product details

C-curve 2-pole MCB for panel builders

The 5SJ4210-7HG41 is a 2-pole miniature circuit breaker from the Siemens SENTRON family, with a C tripping characteristic — the standard choice for protecting motor circuits, lighting, and general-purpose loads where inrush currents are moderate. Rated breaking capacity is 10 kA per EN 60898 and 15 kA per IEC 60947-2 at 400 V AC, giving headroom for most commercial and light industrial panel applications without needing upstream current-limiting fuses. Occupies 2 modular width units (36 mm) on standard DIN rail, with a depth of 70 mm — fits the common 4-module-per-inch footprint used across European panel layouts.

Breaking capacity and selectivity planning

The dual-rated breaking capacity — 10 kA to EN 60898 and 15 kA to IEC 60947-2 — means this MCB can be specified under either standard. The IEC 60947-2 figure is the one to use for industrial control panels where the standard requires performance coordination with upstream devices. Rated insulation voltage (Ui) is 440 V AC, and the overvoltage category is 3 with pollution degree 3 — suitable for fixed installations where transient overvoltages are expected, such as main distribution boards. The C-curve trips at 5 to 10 times rated current, which provides good selectivity with downstream B-curve MCBs on lighting circuits while still clearing moderate overloads on motor feeders.

Sourcing and lifecycle status

The 5SJ4210-7HG41 is a current-catalog item within the SENTRON 5SJ4 series. No official successor or replacement has been announced, and the design is stable for ongoing panel builds.

MPN
5SJ4210-7HG41