Skip to main content
Siemens 6EP3333-6SB00-0AY0

Siemens 6EP3333-6SB00-0AY0 Power Supply, 4 A, 24 VDC

MPN 6EP3333-6SB00-0AY0
Active

Siemens SITOP PSU8200, 6EP3333-6SB00-0AY0, 24 V DC / 4 A regulated power supply, 100-240 V AC input, DIN rail mount, IP20.

$72.39 – $165.00 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

6EP3333-6SB00-0AY0 specifications
ParameterValue
Fuse protection typeinternal
Voltage24 V
Power96 W
Frequency47 ... 63 Hz
Phases1-phase
IP ratingIP20
Depth53 mm
Width72 mm
Height90 mm
Efficiency89.1%

Product details

The Siemens 6EP3333-6SB00-0AY0 is a 24 V DC regulated power supply from the SITOP PSU8200 series, rated for a continuous 4 A output. Input accepts 100–240 V AC at 47–63 Hz, so it handles both 50 Hz and 60 Hz line feeds without adjustment. The 24 V DC output is galvanically isolated, delivering SELV per EN 60950-1 and EN 50178 — meaning the output is safe to touch and suitable for powering PLCs, sensors, and I/O modules in a control panel.

The headline rating is 4 A continuous at 24 V DC, but that's only valid up to +55 °C ambient. Above that, up to +70 °C, you derate 2 % per Kelvin — so at 60 °C you're looking at about 3.6 A usable, and at 70 °C roughly 2.8 A. If your cabinet runs hot, size the load accordingly. The internal fuse is rated for a maximum I²t of 2.5 A²·s, which limits inrush. The recommended upstream protection is a 10 A B-curve or 6 A C-curve miniature circuit breaker — that's the feeder breaker spec, not the output load breaker. MTBF at 40 °C is listed at 2,391,480 hours — roughly 273 years of continuous operation. That's a calculated figure under ideal conditions, but it tells you the design is solid-state and fanless, with no wear items beyond the electrolytic caps.

Mounts via snap-on to DIN rail EN 60715, or can be direct-mounted in different positions. Clearance: 20 mm top and bottom, zero left and right — so you can pack units tight side-by-side, but need breathing room above and below for convection cooling. No ATEX or IECEx certification, so not for hazardous locations.

Approvals and compliance — what the nameplate carries

cULus-Listed under UL 508 and CSA C22.2 No. 107.1 (File E197259), plus cURus-Recognized under UL 60950 and CSA C22.2 No. 60950 (File E151273). Also carries CE and EAC marks, plus DNV GL marine type approval. No NEC Class 2 rating, no FM registration, no UL hazloc.

MPN
6EP3333-6SB00-0AY0